Worked example
Example: Cyclone 2 m³/s, inlet 0.5 x 0.25 m, outlet 0.5 m, 0.85 kg/m³. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow through one cyclone (actual) | 7,200.0 m³/h |
| Gas density | 0.85000 kg/m³ |
| Inlet height | 500.00 mm |
| Inlet width | 250.00 mm |
| Gas outlet (vortex finder) diameter | 500.00 mm |
| Shepherd–Lapple constant | 16.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Cyclone pressure drop | 88.756 mmWC |
| Number of inlet velocity heads | 8.0000 |
| Inlet velocity | 16.000 m/s |
| Inlet velocity pressure | 11.095 mmWC |
Open this example in the calculator and change any input.
Formula
\(v_i = \frac{Q}{a\,b} \qquad p_{d,i} = \frac{\rho\,v_i^2}{2} \qquad N_H = K\,\frac{a\,b}{D_e^2} \qquad \Delta p = N_H\,p_{d,i}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | gas flow through one cyclone | m³/s |
| \(\rho\) | gas density | kg/m³ |
| \(a\) | inlet height | m |
| \(b\) | inlet width | m |
| \(D_e\) | gas outlet diameter | m |
| \(K\) | Shepherd–Lapple constant | – |
| \(\Delta p\) | cyclone pressure drop | Pa |
| \(N_H\) | number of inlet velocity heads | – |
| \(v_i\) | inlet velocity | m/s |
| \(p_{d,i}\) | inlet velocity pressure | Pa |
Method and standards
The velocity-head method of Shepherd and Lapple (Industrial and Engineering Chemistry, 1939 and 1940), widely used for preliminary cyclone design.
Where it is used
- Sizing mechanical dust collectors and cyclones.
- Estimating ID fan pressure for a cyclone.
- Comparing cyclone designs.
Common mistakes
- Using normal instead of actual gas density.
- Ignoring the effect of dust load on pressure drop.
- Using inlet velocity outside the design range.
Assumptions and limits
- Clean gas; dust loading usually lowers the pressure drop slightly.
- Empirical: accurate to about ±30 %; use the maker's figure for the final design.
- Collection efficiency is not calculated here.
References
- Shepherd and Lapple
- Ind. Eng. Chem. 31 (1939) 972; 32 (1940) 605
Questions and answers
How is cyclone pressure drop calculated?
Δp = N_H·ρv_i²/2 with N_H = K·a·b/D_e². A cyclone with a 0.5 × 0.25 m inlet and 0.5 m outlet passing 2 m³/s of gas at 0.85 kg/m³ has an inlet velocity of 16 m/s, 8 velocity heads and a drop of 870 Pa.
What is K?
An empirical constant of Shepherd and Lapple: 16 for a plain tangential inlet and 7.5 with an inlet vane.
Is this for one tube of a multiclone?
Yes, enter the flow per tube and the tube's dimensions; the tubes are in parallel, so the drop is the same for the whole unit.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.