Worked example
Example: 1500 mg/Nm3, 1.5 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| SO₂ (dry, normal) | 1,500.0 mg/Nm³ |
| Share of SO₂ converted to SO₃ | 1.5000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| SO₃ (dry, normal) | 28.120 mg/Nm³ |
| SO₃ by volume (dry) | 7.8728 ppm |
| SO₂ by volume (dry, as entered, before conversion) | 524.85 ppm |
Open this example in the calculator and change any input.
Formula
\(c_{SO_3} = c_{SO_2} f \frac{M_{SO_3}}{M_{SO_2}}, \quad y = \frac{c}{M}V_m\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(c_{SO_2}\) | SO₂ (dry, normal) | kg/m³ |
| \(f\) | Share of SO₂ converted to SO₃ | - |
| \(c_{SO_3}\) | SO₃ (dry, normal) | kg/m³ |
| \(y_{SO_3}\) | SO₃ by volume (dry) | - |
| \(y_{SO_2}\) | SO₂ by volume (dry, as entered, before conversion) | - |
Method and standards
Mass balance with IUPAC molar masses: the SO₃ formed is the converted share of the SO₂ entered; volume fractions on the molar volume at 0 °C and 1 atm.
Where it is used
- Cold-end corrosion studies.
- SCR design.
Common mistakes
- SO₂ ppm entered as mg/Nm³.
Assumptions and limits
- Dry, normal basis. The SO₂ entered is taken as the SO₂ before conversion; its volume fraction is not reduced by the share converted.
- For the acid dew point calculator, which works on wet gas, multiply the dry SO₃ fraction by (1 − water vapour fraction).
References
- Mass balance with IUPAC molar masses; ppm on the molar volume at 0 °C
- 1 atm
Questions and answers
What conversion?
Around 1–3 % in boilers; vanadium in oil ash and SCR catalysts raise it.
Why does SO₃ matter?
It sets the acid dew point and corrosion of the air heater cold end.
With SCR?
SO₃ and ammonia slip form ammonium bisulphate deposits.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.