NOx and CO: lb/MMBtu ↔ ppmvd at 3 % O₂ (Burners)

Factor between NOx or CO in lb/MMBtu and ppmvd at 3 % O₂, from flue gas per MMBtu, molar mass, moisture and oxygen (Ganapathy Eq. 21).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textileBurner and furnaceStack and chimney

Inputs

Examples: Ganapathy: natural gas 0 % excess, 0.1 lb/MMBtuGanapathy: No. 2 oil, 30 % excess

Ganapathy Table 2.10: natural gas 768–966, No. 2 oil 790–938 lb/MMBtu.
The default 0 % is gas from theoretical air; enter the O₂ that goes with the flue gas flow and moisture above.

Results

Ganapathy shows the factor hardly changes with excess air: about 832 (NOx) and 1367 (CO) for natural gas, 783 and 1286 for No. 2 oil.

ppmvd NOx per lb/MMBtu832.51
ppmvd CO per lb/MMBtu1,367.4
NOx at the entered rate83.251ppm
CO at the entered rate136.74ppm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: natural gas 0 % excess, 0.1 lb/MMBtu. The inputs, in the units selected above:

InputValue
Emission per unit heat fired (HHV)0.10000 lb/MMBtu
Wet flue gas per unit heat fired (HHV)769.00 lb/MMBtu
Wet flue gas molar mass27.520 kg/kmol
Water vapour (vol, wet)19.910 %
Oxygen (vol, wet)0 %
Reference oxygen (dry)3.0000 %

Applying the formula below gives:

ResultValue
ppmvd NOx per lb/MMBtu832.51
ppmvd CO per lb/MMBtu1,367.4
NOx at the entered rate83.251 ppm
CO at the entered rate136.74 ppm

Open this example in the calculator and change any input.

Formula

\(V_d = 10^6\,Y\,\frac{N}{M_i}\cdot\frac{MW}{W_{gm}}\cdot\frac{21 - O_{2,ref}}{21 - O_2Y}, \quad Y = \frac{1}{1 - H_2O}\)

Variables

Symbol Meaning SI unit
\(N\) Emission per unit heat fired (HHV) kg/J
\(W_{gm}\) Wet flue gas per unit heat fired (HHV) kg/J
\(MW\) Wet flue gas molar mass kg/kmol
\(H_2O\) Water vapour (vol, wet) -
\(O_2\) Oxygen (vol, wet) -
\(O_{2,ref}\) Reference oxygen (dry) -
\(k_{NO_x}\) ppmvd NOx per lb/MMBtu -
\(k_{CO}\) ppmvd CO per lb/MMBtu -
\(V_{NO_x}\) NOx at the entered rate -
\(V_{CO}\) CO at the entered rate -

Method and standards

Ganapathy's Eq. (21) with M_i = 46.005 (NO₂) and 28.010 (CO) kg/kmol from IUPAC atomic masses. The factors are per lb/MMBtu (HHV); for kg/GJ, convert the emission first (1 lb/MMBtu = 0.4299 kg/GJ).

Where it is used

  • Burner guarantees.
  • Permit conversions for package boilers.

Common mistakes

  • Using wet oxygen in the correction.
  • Mixing HHV and LHV basis.

Assumptions and limits

  • Flue gas analysis per unit heat known, on the HHV basis, with its moisture and O₂ from the same case. The default O₂ is 0 % (theoretical air).

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q2.26b
  • Eq. (21) and Table 2.10

Questions and answers

Why is the factor nearly constant?

More excess air dilutes the gas, but the oxygen correction removes the dilution again.

What is 0.1 lb/MMBtu of NOx on gas?

About 83 ppmvd at 3 % O₂.

Is this the EPA F-factor method?

It is equivalent; the F-factor method uses dry gas volume per unit heat instead of the flue gas mass.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.