FireCADCalc

Dust Concentration: % by Weight ↔ g/m³ and Grains/ft³

Converts the ash or dust in flue gas from % by weight to g per actual or normal cubic metre and grains per standard cubic foot (Ganapathy Q2.16b).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperDust collector (ESP, bag filter, cyclone)

Inputs

Examples: Ganapathy: 1.5 % at 400 °FBiomass boiler 0.5 % at 160 °C

Results

Gas density at t0.73489kg/m³
Concentration, actual11.023g/m³
Concentration per US standard ft³ (60 °F, 14.696 psia)7.9687gr/scf
Concentration at 0 °C, 101.325 kPa19,274mg/Nm³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 1.5 % at 400 °F. The inputs, in the units selected above:

InputValue
Ash in the flue gas (by weight, wet gas)1.5000 %
Gas temperature204.44 °C
Gas pressure (absolute)101.33 kPa
Gas molar mass (wet gas)28.800 kg/kmol

Applying the formula below gives:

ResultValue
Gas density at t0.73488 kg/m³
Concentration, actual11.023 g/m³
Concentration per US standard ft³ (60 °F, 14.696 psia)7.9687 gr/scf
Concentration at 0 °C, 101.325 kPa19,274 mg/Nm³

Open this example in the calculator and change any input.

Formula

\(C_a = A\,\rho_g, \quad \rho_g = \frac{p\,MW}{R\,T}\)

\(C_s = A\,\frac{p_0\,MW}{R\,T_s}, \quad C_N = A\,\frac{p_0\,MW}{R\,T_N}\)

Variables

Symbol Meaning SI unit
\(A\) Ash in the flue gas (by weight) -
\(t\) Gas temperature K
\(p\) Gas pressure (absolute) Pa
\(MW\) Gas molar mass kg/kmol
\(\rho_g\) Gas density at t kg/m³
\(T\) gas temperature \(t\) in kelvin K
\(R\) universal gas constant, 8314.46 J/(kmol·K)
\(p_0\) reference pressure, 101 325 Pa
\(T_s\) standard temperature, 60 °F = 288.71 K
\(T_N\) normal temperature, 0 °C = 273.15 K
\(C_a\) Concentration, actual kg/m³
\(C_s\) Concentration at 60 °F (standard ft³) kg/m³
\(C_N\) Concentration at 0 °C, 101.325 kPa kg/m³

Method and standards

Definition with ideal-gas density (Ganapathy uses 39.5/(460 + t) lb/ft³ for MW 28.8).

Where it is used

  • Dust collector sizing.
  • Emission reporting.

Common mistakes

  • Mixing actual and normal volumes.
  • Using wet and dry bases together.

Assumptions and limits

  • Ideal gas; dust volume negligible.
  • The ash share and molar mass are for the wet gas as it flows. Emission limits are usually quoted on dry gas at a reference O₂; convert with the emission O₂ correction calculator.
  • \(C_a\) is per actual volume at the gas temperature. \(C_s\) and \(C_N\) are the same concentration per standard volume: gr/scf is per US standard cubic foot (60 °F, 14.696 psia), mg/Nm³ per normal cubic metre (0 °C, 101.325 kPa), and the units convert between the two reference states.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q2.16b
  • Eq. (12b)
  • Ideal-gas density; standard 60 °F (288.71 K) and normal 0 °C at 101.325 kPa

Questions and answers

Why grains per cubic foot?

US dust-collector makers quote loadings in grains/acf or grains/scf; 1 grain = 64.8 mg.

What does Ganapathy's example give?

1.5 % ash at 400 °F: 4.8 grains/acf, or 8.0 grains/scf at 60 °F.

Actual or standard?

Collectors are sized on actual volume; emission limits use normal or standard volume.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.