FireCADCalc

Bag Filter Sizing (Cloth Area and Number of Bags)

Cloth area and number of bags of a bag filter (fabric filter) from the gas flow, the air-to-cloth ratio and the bag size, with an allowance for compartments offline.

Thermal power plantSugar mill and cogenerationChemical and fertiliserPulp and paperBoilerStack and chimneyDust collector (ESP, bag filter, cyclone)

Inputs

Examples: Boiler 20 m³/s, 1.0 m/min, bags 160 mm x 6 mBagasse 30 m³/s, 0.9 m/min, 150 mm x 8 m, 1 compartment offline 12 %Small 3 m³/s, 1.2 m/min, 130 mm x 3 m

m³ of gas per m² of cloth per minute. Depends on the dust, the bag fabric and the cleaning method; take it from the filter maker or your specification.

Results

Number of bags438.00
Net cloth area at the air-to-cloth ratio1,200.0m²
Cloth area to install1,320.0m²
Cloth area of one bag3.0159m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Boiler 20 m³/s, 1.0 m/min, bags 160 mm x 6 m. The inputs, in the units selected above:

InputValue
Gas flow (actual, at filter temperature)72,000 m³/h
Air-to-cloth ratio (filtration velocity)1.0000 m/min
Bag diameter160.00 mm
Bag length6.0000 m
Extra area for a compartment offline or cleaning10.000 %

Applying the formula below gives:

ResultValue
Number of bags438.00
Net cloth area at the air-to-cloth ratio1,200.0 m²
Cloth area to install1,320.0 m²
Cloth area of one bag3.0159 m²

Open this example in the calculator and change any input.

Formula

\(A_f = \frac{Q}{v_f} \qquad A_i = A_f\,(1 + x_s) \qquad A_b = \pi\,D_b\,L_b \qquad N = \left\lceil \frac{A_i}{A_b} \right\rceil\)

Variables

Symbol Meaning SI unit
\(Q\) gas flow at filter temperature m³/s
\(v_f\) air-to-cloth ratio (filtration velocity) m/s
\(D_b\) bag diameter m
\(L_b\) bag length m
\(x_s\) extra area for a compartment offline or cleaning –
\(N\) number of bags –
\(A_f\) net cloth area m²
\(A_i\) cloth area to install m²
\(A_b\) cloth area of one bag m²

Method and standards

The air-to-cloth (filtration velocity) method used throughout fabric filter design: the cloth area carries the gas at the chosen superficial velocity through the fabric.

Where it is used

  • Sizing bag filters after boilers, dryers and kilns.
  • Checking an existing filter for a higher gas flow.
  • Comparing pulse-jet and reverse-air designs.

Common mistakes

  • Using normal instead of actual gas volume at the filter temperature.
  • Choosing an air-to-cloth ratio without considering the dust.
  • Forgetting off-line cleaning compartments in the cloth area.

Assumptions and limits

  • Cylindrical bags; pleated cartridges have more area per element.
  • The bag count is rounded up; a ratio that is a whole number to within one part in 10⁹ is not rounded up a further bag.
  • A warning appears for an air-to-cloth ratio outside about 0.3–2.5 m/min.
  • The air-to-cloth ratio sets the area; pressure drop, can velocity and bag life are the filter maker's checks.

References

  • Fabric filter design practice (air-to-cloth ratio method)

Questions and answers

How do I size a bag filter?

Cloth area = gas flow ÷ air-to-cloth ratio. 20 m³/s at 1.0 m/min needs 1 200 m² of cloth; with 10 % extra for a compartment offline, 1 320 m², or 438 bags of 160 mm × 6 m.

Which air-to-cloth ratio?

It depends on the dust, the bag fabric and the cleaning method (pulse jet allows higher ratios than reverse air). Take it from the filter maker or your specification.

Is the gas flow actual or normal?

Actual, at the gas temperature and pressure at the filter.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.