Worked example
Example: Boiler 20 m³/s, 1.0 m/min, bags 160 mm x 6 m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow (actual, at filter temperature) | 72,000 m³/h |
| Air-to-cloth ratio (filtration velocity) | 1.0000 m/min |
| Bag diameter | 160.00 mm |
| Bag length | 6.0000 m |
| Extra area for a compartment offline or cleaning | 10.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Number of bags | 438.00 |
| Net cloth area at the air-to-cloth ratio | 1,200.0 m² |
| Cloth area to install | 1,320.0 m² |
| Cloth area of one bag | 3.0159 m² |
Open this example in the calculator and change any input.
Formula
\(A_f = \frac{Q}{v_f} \qquad A_i = A_f\,(1 + x_s) \qquad A_b = \pi\,D_b\,L_b \qquad N = \left\lceil \frac{A_i}{A_b} \right\rceil\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | gas flow at filter temperature | m³/s |
| \(v_f\) | air-to-cloth ratio (filtration velocity) | m/s |
| \(D_b\) | bag diameter | m |
| \(L_b\) | bag length | m |
| \(x_s\) | extra area for a compartment offline or cleaning | – |
| \(N\) | number of bags | – |
| \(A_f\) | net cloth area | m² |
| \(A_i\) | cloth area to install | m² |
| \(A_b\) | cloth area of one bag | m² |
Method and standards
The air-to-cloth (filtration velocity) method used throughout fabric filter design: the cloth area carries the gas at the chosen superficial velocity through the fabric.
Where it is used
- Sizing bag filters after boilers, dryers and kilns.
- Checking an existing filter for a higher gas flow.
- Comparing pulse-jet and reverse-air designs.
Common mistakes
- Using normal instead of actual gas volume at the filter temperature.
- Choosing an air-to-cloth ratio without considering the dust.
- Forgetting off-line cleaning compartments in the cloth area.
Assumptions and limits
- Cylindrical bags; pleated cartridges have more area per element.
- The bag count is rounded up; a ratio that is a whole number to within one part in 10⁹ is not rounded up a further bag.
- A warning appears for an air-to-cloth ratio outside about 0.3–2.5 m/min.
- The air-to-cloth ratio sets the area; pressure drop, can velocity and bag life are the filter maker's checks.
References
- Fabric filter design practice (air-to-cloth ratio method)
Questions and answers
How do I size a bag filter?
Cloth area = gas flow ÷ air-to-cloth ratio. 20 m³/s at 1.0 m/min needs 1 200 m² of cloth; with 10 % extra for a compartment offline, 1 320 m², or 438 bags of 160 mm × 6 m.
Which air-to-cloth ratio?
It depends on the dust, the bag fabric and the cleaning method (pulse jet allows higher ratios than reverse air). Take it from the filter maker or your specification.
Is the gas flow actual or normal?
Actual, at the gas temperature and pressure at the filter.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.