Worked example
Example: 1 % N, 25 % conversion. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel fired | 10.000 t/h |
| Nitrogen in the fuel (as fired) | 1.0000 % |
| Conversion of fuel N to NO | 25.000 % |
| Flue gas flow (dry, normal) | 100,000 Nm³/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Fuel NOx (as NO₂) | 82.111 kg/h |
| Fuel NOx concentration (as NO₂, dry) | 821.11 mg/Nm³ |
Open this example in the calculator and change any input.
Formula
\(\dot m_{NO_x} = \dot m_f\,N\,f\,\frac{M_{NO_2}}{M_N}, \quad c = \frac{\dot m_{NO_x}}{\dot V_n}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_f\) | Fuel fired | kg/s |
| \(N\) | Nitrogen in the fuel (as fired) | - |
| \(f\) | Conversion of fuel N to NO | - |
| \(\dot V_n\) | Flue gas flow (dry, normal) | Nm³/s |
| \(\dot m_{NO_x}\) | Fuel NOx (as NO₂) | kg/s |
| \(c_{NO_x}\) | Fuel NOx concentration (as NO₂, dry) | kg/m³ |
Method and standards
Mass balance of fuel nitrogen: the share converted to NO is reported as NO₂ mass using IUPAC molar masses. The conversion share carries the whole prediction and is your input.
Where it is used
- Emission estimates for new fuels.
- SNCR sizing input.
Common mistakes
- NO mass instead of NO₂.
Assumptions and limits
- Dry, normal basis, at the actual O₂: not corrected to a reference O₂. Correct it with the emission O₂ correction calculator before comparing with a limit.
- The flue gas flow is not checked against the fuel fired; take it from the combustion calculator for the same fuel and excess air.
- Thermal NOx is not included.
References
- Mass balance N → NO
- reported as NO₂ (IUPAC molar masses); conversion share as user input
Questions and answers
What conversion?
Often quoted as 10–40 %, falling as nitrogen content rises and with air staging; it depends on the fuel and burner, so use measured or burner-maker data. The calculator does not check it.
Why report as NO₂?
Regulations express NOx as NO₂ mass, whatever the NO/NO₂ split.
Grate and FBC boilers?
Low furnace temperatures make fuel NOx the main part.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.