FireCADCalc

Gas Turbine NOx and CO: lb/h to ppmvd at 15 % O₂

Converts NOx (as NO₂) and CO mass flows in gas turbine or HRSG exhaust to ppm by volume dry, corrected to a reference oxygen (15 %), by Ganapathy's Eqs. (19)–(20).

Thermal power plantRefinery and petrochemicalChemical and fertiliserStack and chimney

Inputs

Examples: Ganapathy: 25 lb/h NOx, 15 lb/h CO in 550,000 lb/hFired HRSG exhaust

21 % in Ganapathy's equations and EU practice; US EPA gas turbine rules often use 20.9 %.

Results

Report NOx as NO₂; duct-burner contributions add to the turbine's own emissions.

NO₂ mole fraction, dry30.739ppm
Correction factor to the reference O₂0.72973
NOx, ppmvd at the reference O₂22.431ppm
CO, ppmvd at the reference O₂22.105ppm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 25 lb/h NOx, 15 lb/h CO in 550,000 lb/h. The inputs, in the units selected above:

InputValue
NOx (as NO₂)11.340 kg/h
CO6.8039 kg/h
Exhaust gas flow (wet)249.48 t/h
Exhaust molar mass (wet gas)28.000 kg/kmol
Water vapour in the exhaust (vol, wet)10.000 %
Oxygen in the exhaust (vol, wet)11.500 %
Reference oxygen (dry)15.000 %
O₂ in air used by the rule21.000 %

Applying the formula below gives:

ResultValue
NO₂ mole fraction, dry30.739 ppm
Correction factor to the reference O₂0.72973
NOx, ppmvd at the reference O₂22.431 ppm
CO, ppmvd at the reference O₂22.105 ppm

Open this example in the calculator and change any input.

Formula

\(V = \frac{w/M_{NO_2}}{W/MW}\cdot\frac{1}{1 - H_2O}, \quad V_{ref} = V\,\frac{O_{2,air} - O_{2,ref}}{O_{2,air} - O_2/(1 - H_2O)}\)

Variables

Symbol Meaning SI unit
\(w_{NO_x}\) NOx (as NO₂) kg/s
\(w_{CO}\) CO kg/s
\(W\) Exhaust gas flow kg/s
\(MW\) Exhaust molar mass kg/kmol
\(H_2O\) Water vapour in the exhaust (vol, wet) -
\(O_2\) Oxygen in the exhaust (vol, wet) -
\(O_{2,ref}\) Reference oxygen (dry) -
\(O_{2,air}\) O₂ in air used by the rule (21 % default; 20.9 % in US EPA practice) -
\(V\) NO₂ mole fraction, dry -
\(F\) Correction factor to the reference O₂ -
\(V_{NO_x}\) NOx, ppmvd at the reference O₂ -
\(V_{CO}\) CO, ppmvd at the reference O₂ -

Method and standards

Ganapathy's mole balance with the standard oxygen correction.

Where it is used

  • Gas turbine and HRSG permits.
  • CEMS checks.

Common mistakes

  • Correcting with wet oxygen.
  • Reporting NOx as NO.

Assumptions and limits

  • Ideal gas; exhaust analysis known. The exhaust flow and molar mass are on the wet basis (\(W/MW\) is the total wet kmol).
  • In US units the NOx and CO flows are shown in lb/h.
  • A note appears when the dry O₂ is above 18 %.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q2.26a
  • Eqs. (19) and (20)
  • Molar masses NO₂ and CO from IUPAC atomic masses

Questions and answers

Why dry and at 15 % O₂?

Regulations for gas turbines compare plants on a dry basis at 15 % oxygen so dilution cannot hide emissions.

Why is NOx counted as NO₂?

Convention: NO converts to NO₂ in the atmosphere.

What does Ganapathy's example give?

25 lb/h NOx and 15 lb/h CO in 550,000 lb/h exhaust give about 22 ppmvd NOx and 22 ppmvd CO at 15 % O₂ by its Eqs. (19)–(20); the printed 16.4 is an arithmetic slip.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.