Worked example
Example: Coal boiler: furnace -5 mmWC, losses 2 600 Pa, stack 180 Pa. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Furnace suction to hold | 4.9966 mmWC |
| Boiler passes, superheater and bank | 91.774 mmWC |
| Economiser | 40.789 mmWC |
| Air heater, gas side | 61.183 mmWC |
| Dust collector (ESP, bag filter, cyclone, scrubber) | 50.986 mmWC |
| Ducts, dampers, stack friction and exit loss | 20.394 mmWC |
| Natural draught of the stack (from the stack draught calculator) | 18.355 mmWC |
| Pressure margin | 0 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| ID fan pressure required (with margin) | 251.77 mmWC |
| Net requirement before margin | 251.77 mmWC |
| Furnace suction plus losses | 270.12 mmWC |
| Gas-side losses | 265.13 mmWC |
Open this example in the calculator and change any input.
Formula
\(\Sigma\Delta p = \Delta p_1 + \Delta p_2 + \Delta p_3 + \Delta p_4 + \Delta p_5 \qquad \Sigma = p_f + \Sigma\Delta p \qquad \Delta p_{net} = \Sigma - \Delta p_s \qquad \Delta p_{ID} = \Delta p_{net}\,(1 + m_p)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_f\) | furnace suction to hold | Pa |
| \(\Delta p_1\) | boiler passes, superheater and bank | Pa |
| \(\Delta p_2\) | economiser | Pa |
| \(\Delta p_3\) | air heater, gas side | Pa |
| \(\Delta p_4\) | dust collector | Pa |
| \(\Delta p_5\) | ducts, dampers, stack friction and exit loss | Pa |
| \(\Delta p_s\) | natural draught of the stack | Pa |
| \(m_p\) | pressure margin | – |
| \(\Delta p_{ID}\) | ID fan pressure required with margin | Pa |
| \(\Delta p_{net}\) | net requirement before margin | Pa |
| \(\Sigma\) | furnace suction plus losses | Pa |
| \(\Sigma\Delta p\) | gas-side losses | Pa |
Method and standards
Steady pressure balance along the gas path of a balanced-draught unit: the ID fan supplies whatever the furnace suction and the losses need beyond the stack's natural draught.
Where it is used
- Checking the draught of balanced-draught boilers.
- Locating where draught is lost.
- ID fan pressure estimates.
Common mistakes
- Forgetting the stack effect of hot gas.
- Mixing static and total pressure.
- Ignoring fouled surfaces that add pressure drop.
Assumptions and limits
- All losses at the same (MCR) flow and gas temperatures.
- Losses scale with about the square of flow; at part load use the losses at that load.
- The pressure margin is your input (FireCAD default 0); the fan sizing applies its own flow margin. It is applied to the net requirement after the stack credit; some specifications apply it to the fan's own resistance before the credit, which gives a slightly higher pressure.
- Use the stack draught at summer conditions, the smallest credit.
- When the stack draught exceeds the requirement the ID fan pressure is shown as zero; the net requirement shows the surplus as a negative value.
References
- Pressure balance along the gas path (balanced draught)
Questions and answers
How do I find the ID fan pressure?
Add the furnace suction you hold and every gas-side loss up to the stack exit, then subtract the stack's natural draught. Furnace −5 mmWC (49 Pa) plus 2 600 Pa of losses less 180 Pa of stack draught leaves 2 469 Pa for the ID fan.
Where do the losses come from?
From the boiler maker for the pressure parts, the dust collector maker, and the duct pressure drop calculator for the ducts; all at MCR flow.
Is the stack draught always a credit?
Yes when the gas is lighter than the air; it is larger in winter and at high gas temperatures. Use the summer value, which is the smallest.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.