Effect of a Fuel's Heating Value on Fuel, Air and Flue Gas

Fuel burnt, combustion air and flue gas per unit of duty for an original and a new fuel of different heating value at the same efficiency and excess air (Ganapathy).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperBoiler

Inputs

Examples: Ganapathy: 11,400 → 9,800 Btu/lb coal, 25 %Oil (745) to natural gas (730)

Results

A poorer fuel raises the fuel and ash handled and the flue gas a little; check mills, feeders, ash systems and fouling, not only the fans.

The same air per MMBtu is used for both fuels; for a change of fuel class choose the new fuel's class.

Design fuel burnt4.9670t/h
New fuel burnt5.7780t/h
Dry air, design fuel51.669t/h
Dry air, new fuel51.669t/h
Flue gas, design fuel56.636t/h
Flue gas, new fuel57.447t/h
Flue gas ratio1.0143

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 11,400 → 9,800 Btu/lb coal, 25 %. The inputs, in the units selected above:

InputValue
Boiler duty30.000 MW
Efficiency (HHV)82.000 %
Fuel (Ganapathy Table 2.4: dry air per MMBtu fired, lb)Bituminous coal (760)
New fuel, if of another class (0 = same as the design fuel)Same as the design fuel
Excess air25.000 %
Design fuel heating value26.516 MJ/kg
New fuel heating value22.795 MJ/kg

Applying the formula below gives:

ResultValue
Design fuel burnt4.9670 t/h
New fuel burnt5.7780 t/h
Dry air, design fuel53.793 t/h
Dry air, new fuel53.793 t/h
Flue gas, design fuel58.760 t/h
Flue gas, new fuel59.571 t/h
Flue gas ratio1.0138

Open this example in the calculator and change any input.

Formula

\(W_f = \frac{Q_{out}}{\eta\,HHV}, \quad W_a = \frac{Q_{out}}{\eta}A_{SI}(1 + EA), \quad W_g = W_a + W_f\)

\(A_{SI}\) is \(A\) (lb/MMBtu) in kg/J; the new fuel uses \(A_2\) when a different class is chosen, otherwise \(A\).

Variables

Symbol Meaning SI unit
\(Q_{out}\) Boiler duty W
\(\eta\) Efficiency (HHV) -
\(A\) theoretical dry air per MMBtu fired, design fuel (Ganapathy Table 2.4) lb/MMBtu
\(EA\) Excess air -
\(HHV_1\) Design fuel heating value J/kg
\(HHV_2\) New fuel heating value J/kg
\(W_{f1}\) Design fuel burnt kg/s
\(W_{f2}\) New fuel burnt kg/s
\(W_a\) Dry air, design fuel kg/s
\(A_2\) air per MMBtu of the new fuel (0 = same as the design fuel) lb/MMBtu
\(W_{a2}\) Dry air, new fuel kg/s
\(W_{g1}\) Flue gas, design fuel kg/s
\(W_{g2}\) Flue gas, new fuel kg/s
\(W_{g2}/W_{g1}\) Flue gas ratio -

Method and standards

Ganapathy's MMBtu method applied to two fuels.

Where it is used

  • Fuel switching studies.
  • Coal procurement decisions.

Common mistakes

  • Assuming the efficiency stays the same with a wetter fuel.

Assumptions and limits

  • Same efficiency and excess air.
  • The whole fuel mass, ash included, is added to the flue gas, as in Ganapathy's method; for a high-ash fuel the gas is slightly overstated.
  • For a change of fuel class, choose the new fuel's air per MMBtu; otherwise the same value is used for both.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q2.14 and Table 2.4

Questions and answers

Why does air not change?

Air per unit of heat fired is nearly constant, so the same duty needs the same air.

Why does flue gas rise?

More fuel mass (moisture and ash) is burnt for the same heat.

What did Ganapathy find?

Switching from 11,400 to 9,800 Btu/lb coal raises flue gas by only about 1.5 %; fans can usually stay.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.