Burner Heat Input, Load and Turndown

Heat input per burner, burner load and turndown ratio, and the boiler firing range with a given number of burners in service.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalPulp and paperBoilerBurner and furnace

Inputs

Examples: 80 MW with 4 of 6 burners, 20 MW max, 6 MW minPackage boiler 12 MW, 1 burner of 14 MW, 2.8 MW minPF boiler 300 MW, 12 burners of 30 MW, 12 MW min

Results

Heat input per burner20.000MW
Burner load, share of maximum100.00%
Burner turndown ratio3.3333
Lowest boiler firing with these burners24.000MW
Highest boiler firing with these burners80.000MW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 80 MW with 4 of 6 burners, 20 MW max, 6 MW min. The inputs, in the units selected above:

InputValue
Total boiler heat input (same GCV or NCV basis as the burner ratings)80.000 MW
Burners in service4.0000 -
Burner maximum rating20.000 MW
Burner minimum stable firing6.0000 MW

Applying the formula below gives:

ResultValue
Heat input per burner20.000 MW
Burner load, share of maximum100.00 %
Burner turndown ratio3.3333
Lowest boiler firing with these burners24.000 MW
Highest boiler firing with these burners80.000 MW

Open this example in the calculator and change any input.

Formula

\(\dot Q_b = \frac{\dot Q}{n} \qquad \lambda = \frac{\dot Q_b}{\dot Q_{max}} \qquad TD = \frac{\dot Q_{max}}{\dot Q_{min}} \qquad \dot Q_{lo} = n\,\dot Q_{min} \qquad \dot Q_{hi} = n\,\dot Q_{max}\)

Variables

Symbol Meaning SI unit
\(\dot Q\) total heat input W
\(n\) burners in service –
\(\dot Q_{max}\) burner maximum rating W
\(\dot Q_{min}\) burner minimum stable firing W
\(\dot Q_b\) heat input per burner W
\(\lambda\) burner load –
\(TD\) turndown ratio –
\(\dot Q_{lo}\) lowest boiler firing W
\(\dot Q_{hi}\) highest boiler firing W

Method and standards

Definitions of burner load and turndown; equal sharing between burners in service.

Where it is used

  • Burner management settings.
  • Choosing burner number and size.
  • Low-load operation planning.

Common mistakes

  • Quoting turndown on a different basis (flow instead of heat).
  • Assuming equal sharing when burners are not balanced.
  • Ignoring minimum load of the mills or fuel system.

Assumptions and limits

  • Equal load on all burners in service.
  • The boiler heat input and the burner ratings must be on the same calorific basis: burner makers often rate on net (NCV) input, while boiler input is often quoted on gross (GCV).

References

  • Definitions of burner load and turndown

Questions and answers

How many burners should be in service?

Enough that each fires between its minimum and maximum. 80 MW with 4 of 6 burners rated 20 MW is 20 MW each, 100 % load; with these 4 burners the boiler can fire from 24 to 80 MW.

What is turndown?

Maximum over minimum stable firing of one burner: 20 MW over 6 MW is 3.3:1. The boiler's turndown with several burners is wider, by switching burners on and off.

Why not run all burners at low load?

Below the minimum stable rating flames become unstable and CO rises; the burner management system must keep each burner above it.

Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.