FireCADCalc

Fuel Oil Heating Value from °API Gravity

Gross (HHV) and net (LHV) heating values, hydrogen content and density of a fuel oil from its °API gravity and sulphur when no ultimate analysis is available.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textileFuel oil and gas system

Inputs

Examples: Ganapathy: 30 °API, 0.5 % SHeavy oil 12 °API, 3.5 % S

Results

Specific gravity at 60 °F0.87616
Density at 60 °F875.28kg/m³
Hydrogen12.058%
Higher heating value45.499MJ/kg
Lower heating value42.940MJ/kg
Higher heating value per litre of oil (60 °F)39.824MJ/L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ganapathy: 30 °API, 0.5 % S. The inputs, in the units selected above:

InputValue
API gravity30.000 -
Sulphur0.50000 %

Applying the formula below gives:

ResultValue
Specific gravity at 60 °F0.87616
Density at 60 °F875.28 kg/m³
Hydrogen12.058 %
Higher heating value45.499 MJ/kg
Lower heating value42.940 MJ/kg
Higher heating value per litre of oil (60 °F)39.824 MJ/L

Open this example in the calculator and change any input.

Formula

\(HHV = 17\,887 + 57.5\,°API - 102.2\,\%S \ \ (\mathrm{Btu/lb}), \quad \%H_2 = F - \frac{2122.5}{°API + 131.5}, \quad LHV = HHV - 91.23\,\%H_2, \quad SG = \frac{141.5}{131.5 + °API}\)

\(\rho = 999.0\,SG, \quad HHV_V = HHV\,\rho\)

Variables

Symbol Meaning SI unit
\(°API\) API gravity -
\(S\) Sulphur -
\(SG\) Specific gravity at 60 °F -
\(\rho\) Density at 60 °F kg/m³
\(H_2\) Hydrogen -
\(HHV\) Higher heating value J/kg
\(LHV\) Lower heating value J/kg
\(HHV_V\) Higher heating value per volume of liquid oil at 60 °F J/m³
\(F\) hydrogen constant by °API band %

Method and standards

Ganapathy's correlations; F = 24.50 (0 to 9 °API), 25.00 (above 9 to 20), 25.20 (above 20 to 30), 25.45 (above 30 to 40): a value on a band edge takes the lower band. The steps make the hydrogen and LHV jump slightly at 9, 20 and 30 °API.

Where it is used

  • Fuel oil purchase checks.
  • Boiler efficiency calculations without an ultimate analysis.

Common mistakes

  • Using the correlation for non-petroleum oils.
  • Entering sulphur as a fraction instead of %.

Assumptions and limits

  • Petroleum fuel oils, 0–40 °API, sulphur 0–6 %.
  • The LHV deducts only the water formed from hydrogen; the oil is taken as water-free.

References

  • Ganapathy
  • Steam Plant Calculations Manual
  • 2nd ed. (Marcel Dekker, 1993)
  • Q2.02
  • Eqs. (4a)
  • (4b)
  • (5) and (6)
  • Water density at 60 °F taken as 999.0 kg/m³

Questions and answers

How accurate is it?

It is an empirical estimate for petroleum fuel oils; use a bomb calorimeter result for contracts and guarantees.

Why does sulphur lower the HHV?

Sulphur replaces carbon and hydrogen, which release far more heat per kilogram.

What is 30 °API?

Specific gravity 0.876. The correlation gives 19,612 Btu/lb HHV with no sulphur and 19,561 Btu/lb (45.50 MJ/kg) at 0.5 % sulphur.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.