Worked example
Example: 10 L natural gas at 15 °C, 6 kg water 15 to 30 °C, 16 g condensate. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas burnt, by the meter | 10.000 L |
| Gas pressure at the meter (absolute) | 1,023.2 mbar |
| Gas temperature at the meter | 15.000 °C |
| Cooling water collected | 6.0000 kg |
| Water inlet temperature | 15.000 °C |
| Water outlet temperature | 30.000 °C |
| Specific heat of water | 4.1868 kJ/(kg·K) |
| Gas meter | Dry meter (dry gas) |
| Steam condensate collected (for the net value) | 16.000 g |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat taken up by the water | 376.81 kJ |
| Gas burnt at 0 °C and 101.325 kPa | 9.5730 L |
| Gross calorific value per m³ at meter conditions | 37,681 kJ/m³ |
| Gross calorific value per Nm³ | 39,362 kJ/Nm³ |
| Net calorific value per Nm³ | 35,281 kJ/Nm³ |
Open this example in the calculator and change any input.
Formula
\(Q = m_w\, c_w\, (T_{out} - T_{in})\)
\(V_N = V_g\, \frac{p_g - p_v}{101.325\ \text{kPa}}\, \frac{273.15\ \text{K}}{T_g}\)
\(GCV = \frac{Q}{V_N}, \quad NCV = GCV - \frac{m_c}{V_N}\, h_{fg,25}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_g\) | Gas burnt, by the meter | m³ |
| \(p_g\) | Gas pressure at the meter (absolute) | Pa |
| \(T_g\) | Gas temperature at the meter | K |
| \(m_w\) | Cooling water collected | kg |
| \(T_{in}\) | Water inlet temperature | K |
| \(T_{out}\) | Water outlet temperature | K |
| \(c_w\) | Specific heat of water | J/(kg·K) |
| \(\text{meter}\) | Gas meter: dry, or wet (water-sealed, gas saturated) | - |
| \(p_v\) | Water vapour pressure at T_g (IF97) for a wet meter; zero for a dry meter | Pa |
| \(m_c\) | Steam condensate collected (for the net value) | kg |
| \(Q\) | Heat taken up by the water | J |
| \(V_N\) | Gas burnt at 0 °C and 101.325 kPa | m³ |
| \(GCV_m\) | Gross calorific value per m³ at meter conditions | J/m³ |
| \(GCV\) | Gross calorific value per Nm³ | J/m³ |
| \(NCV\) | Net calorific value per Nm³ | J/m³ |
Method and standards
Heat from the burnt gas equals the heat taken up by the cooling water; the gas volume is corrected to 0 °C and 101.325 kPa by the ideal gas law.
Worked example
10 L of gas at 15 °C and 1023 mbar is burnt; 6 kg of water warms from 15 °C to 30 °C; 16 g of condensate is collected.
- Q = 6 × 4.1868 × 15 = 376.8 kJ
- V_N = 10 × 1023.25/1013.25 × 273.15/288.15 = 9.573 L
- GCV = 376.8 / 0.009573 = 39 360 kJ/Nm³ = 39.4 MJ/Nm³
- NCV = 39 360 − 0.016/0.009573 × 2442 = 35 280 kJ/Nm³
Where it is used
- Boiler attendant and operator examinations.
- Testing producer, biogas or LPG supplies.
- Checking a gas supplier's calorific value.
Common mistakes
- Using the meter volume without correction.
- Using the total water when only part was collected over the test time.
- Mixing per m³ and per Nm³ values.
Assumptions and limits
- Dry gas at the meter unless the wet meter is chosen, when the gas is taken as saturated at the meter temperature; no heat loss.
- If the condensate's latent heat exceeds the heat measured, no net value is shown.
- Normal conditions 0 °C, 101.325 kPa.
References
- Junkers (Boys) gas calorimeter heat balance (textbook)
- Latent heat of water at 25 °C from IAPWS-IF97
Questions and answers
What does 10 L of gas heating 6 kg of water by 15 K give?
376.8 kJ. At 15 °C and 1023 mbar the 10 L is 9.57 L at 0 °C and 1 atm, so GCV = 39.4 MJ/Nm³; with 16 g of condensate the NCV is 35.3 MJ/Nm³.
Why correct the volume?
A gas meter reads the volume at its own pressure and temperature; calorific values are quoted per normal cubic metre.
What is the condensate for?
It is the water formed by burning the hydrogen; its latent heat is the difference between gross and net values.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.