Worked example
Example: 70 % Indian coal + 30 % imported. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Share of fuel 1 in the blend, by mass | 70.000 % |
| Gross calorific value | 15,500 kJ/kg |
| Ash | 38.000 % |
| Sulphur | 0.50000 % |
| Moisture | 10.000 % |
| Price per metric tonne (your currency) | 4,500.0 - |
| Gross calorific value | 24,000 kJ/kg |
| Ash | 12.000 % |
| Sulphur | 0.80000 % |
| Moisture | 15.000 % |
| Price per metric tonne (your currency) | 9,000.0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Blend gross calorific value | 18,050 kJ/kg |
| Blend ash | 30.200 % |
| Blend sulphur | 0.59000 % |
| Blend moisture | 11.500 % |
| Blend price per tonne | 5,850.0 |
| Blend cost per GJ | 324.10 |
Open this example in the calculator and change any input.
Formula
\(GCV_b = s_1 GCV_1 + s_2 GCV_2 \quad (s_2 = 1 - s_1) \qquad A_b, S_b, M_b, c_b \ \text{likewise} \qquad c_{GJ} = \frac{c_b}{GCV_b \times 1000\ \text{kg/t} / 10^9\ \text{J/GJ}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(s_1\) | share of fuel 1 | – |
| \(GCV_1\) | GCV of fuel 1 | J/kg |
| \(A_1\) | ash of fuel 1 | – |
| \(S_1\) | sulphur of fuel 1 | – |
| \(M_1\) | moisture of fuel 1 | – |
| \(c_1\) | price of fuel 1 per metric tonne | currency/t |
| \(GCV_2\) | GCV of fuel 2 | J/kg |
| \(A_2\) | ash of fuel 2 | – |
| \(S_2\) | sulphur of fuel 2 | – |
| \(M_2\) | moisture of fuel 2 | – |
| \(c_2\) | price of fuel 2 per metric tonne | currency/t |
| \(GCV_b\) | blend GCV | J/kg |
| \(A_b\) | blend ash | – |
| \(S_b\) | blend sulphur | – |
| \(M_b\) | blend moisture | – |
| \(c_b\) | blend price per metric tonne | currency/t |
| \(c_{GJ}\) | blend cost per GJ of fuel GCV | currency/GJ |
| \(s_2\) | share of fuel 2 | – |
Method and standards
Mass-weighted averages of as-fired properties; cost per GJ from price per tonne and GCV.
Where it is used
- Planning coal blends for cost and boiler limits.
- Co-firing biomass with coal.
- Meeting sulphur or ash limits with a blend.
Common mistakes
- Mixing as-fired and air-dried analyses.
- Blending by volume and calling it mass.
- Assuming ash fusion behaves linearly.
Assumptions and limits
- Both fuels on the same (as-fired) basis; mixing air-dried and as-received analyses cannot be detected.
- Prices are per metric tonne (1000 kg) in every unit system.
- The cost per GJ is per GJ of fuel heat (GCV) fired; it does not include the different boiler efficiency the two fuels may give.
References
- Mass-weighted mixing of as-fired properties
Questions and answers
What GCV does a coal blend have?
70 % Indian coal at 15.5 MJ/kg with 30 % imported coal at 24.0 MJ/kg gives 18.05 MJ/kg, 30 % ash and 0.59 % sulphur; at 4500 and 9000 per tonne the blend costs 5850 per tonne, 324 per GJ.
Are all properties linear?
Calorific value, ash, sulphur and moisture mix by mass. Ash fusion, slagging and grindability do not, so test the blend.
Mass or volume share?
Mass. Fuels of different bulk density blended by volume (bucket counts) give a different mass share.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.