Worked example
Example: Ganapathy: fuel oil, 15 %, 300 °F air. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Lower heating value | 39.542 MJ/kg |
| Higher heating value | 41.868 MJ/kg |
| Fuel (Ganapathy Table 2.4: dry air per MMBtu fired, lb) | Furnace oil and lignite (745) |
| Excess air | 15.000 % |
| Combustion air temperature | 148.89 °C |
| Reference (ambient) temperature | 26.667 °C |
| Ash in the fuel | 0 % |
| Air specific heat | 1.0467 kJ/(kg·K) |
| Mean specific heat of the products | 1.3398 kJ/(kg·K) |
| Allowance for dissociation and radiation | 4.0000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Temperature rise of the products | 1,886.9 K |
| Adiabatic combustion temperature | 1,913.6 °C |
| Estimated actual combustion temperature | 1,838.1 °C |
Open this example in the calculator and change any input.
Formula
\(\Delta t_c = \frac{LHV + A\alpha\,HHV\,c_{pa}(t_a - t_{ref})}{(1 - a + A\alpha\,HHV)\,c_{pg}}, \quad \alpha = 1 + EA\)
\(t_c = t_{ref} + \Delta t_c, \quad t_c' = t_{ref} + \Delta t_c\,(1 - \delta)\)
\(A\) is converted from lb/MMBtu to kg/J before use.
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(LHV\) | Lower heating value | J/kg |
| \(HHV\) | Higher heating value | J/kg |
| \(A\) | theoretical dry air per MMBtu fired for the fuel chosen (Ganapathy Table 2.4) | lb/MMBtu |
| \(EA\) | Excess air | - |
| \(t_a\) | Combustion air temperature | K |
| \(t_{ref}\) | Reference (ambient) temperature | K |
| \(a\) | Ash in the fuel | - |
| \(c_{pa}\) | Air specific heat | J/(kg·K) |
| \(c_{pg}\) | Mean specific heat of the products | J/(kg·K) |
| \(\delta\) | Allowance for dissociation and radiation | - |
| \(\Delta t_c\) | Temperature rise of the products | K |
| \(t_c\) | Adiabatic combustion temperature | K |
| \(t_c'\) | Estimated actual combustion temperature | K |
Method and standards
Ganapathy's Eq. (11), written as a rise above the reference temperature.
Where it is used
- Burner and furnace checks.
- Refractory selection.
Common mistakes
- Using the adiabatic value as furnace exit temperature.
- Mixing HHV and LHV.
Assumptions and limits
- Mean product specific heat constant.
- Fuel sensible heat, air humidity and the sensible heat carried away by ash are neglected.
- The LHV must not exceed the HHV.
References
- Ganapathy
- Steam Plant Calculations Manual
- 2nd ed. (Marcel Dekker, 1993)
- Q2.15
- Eq. (11)
- and Table 2.4
Questions and answers
Why reduce by 3–5 %?
Dissociation and radiation keep real flames below the adiabatic value. The allowance reduces the rise above the reference temperature, not the absolute temperature.
Why is the denominator 1 + air?
One kilogram of fuel plus A·α·HHV kilograms of air make the products; ash leaves as solids.
What specific heats should I use?
Ganapathy uses 0.25 Btu/lb·°F for air and 0.32 for the products (1047 and 1340 J/kg·K).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.