Boiler: fuel to fans

From the fuel analysis to combustion air, efficiency by losses, fuel firing rate and the FD and ID fans, each step feeding the next.

  1. Fuel and combustion
  2. Boiler efficiency by losses
  3. Fuel firing rate
  4. Forced draught fan
  5. Induced draught fan

1 Fuel and combustion

Air needed and flue gas produced per kg of fuel, and the calorific value used in the later steps. Open this step in its calculator

Ultimate analysis, as fired, by mass

Leave 0 to estimate by Channiwala–Parikh.
Gross calorific value used18,613kJ/kg
GCV estimate, Channiwala–Parikh18,613kJ/kg
GCV estimate, Dulong (for comparison)19,475kJ/kg
Net calorific value17,605kJ/kg
Stoichiometric oxygen1.4316kg/kg
Theoretical dry air6.1858kg/kg
Actual dry air7.4230kg/kg
Actual wet air7.5195kg/kg
Wet flue gas8.1695kg/kg
Dry flue gas7.6602kg/kg
Water vapour in flue gas0.50926kg/kg
Wet flue gas volume (normal)6.2260Nm³/kg
CO₂ in wet flue gas13.525%
H₂O in wet flue gas10.177%
N₂ in wet flue gas72.163%
Ar in wet flue gas0.85799%
O₂ in wet flue gas3.2213%
SO₂ in wet flue gas0.056146%
O₂ in dry flue gas (analyser reading)3.5863%

2 Boiler efficiency by losses

ASME PTC 4 losses from the same fuel and excess air. Open this step in its calculator

Operating data

Ash flow × carbon in ash. 0.5 % of fuel is typical for a well-run grate or bed.
25 °C means the sensible heat in ash is not counted.

Losses entered directly

Fraction of fuel input; ABMA curve or measured.
Gross calorific value used18,613kJ/kg
Net calorific value17,605kJ/kg
Dry gas loss4.7298%
Water from hydrogen in fuel4.4684%
Moisture in fuel1.4287%
Moisture in air0.11232%
Unburned CO0.13311%
Unburned carbon in residue0.90600%
Sensible heat in residue0%
Surface radiation and convection1.0000%
Unaccounted0.50000%
Total losses13.278%
Credit: entering dry air above 25 °C0.20037%
Credit: moisture in entering air0.004835%
Total credits0.20521%
Fuel efficiency, gross (HHV) basis86.927%
Efficiency, net (LHV) basis91.903%

3 Fuel firing rate

Fuel needed for the steam output, at the efficiency and GCV of step 2. Open this step in its calculator

  • Boiler efficiency (on GCV): 86.927 % from Fuel efficiency, gross (HHV) basis (step 2)
  • Gross calorific value of the fuel, as fired: 18,613 kJ/kg from Gross calorific value used (step 2)

Heat output entered

Steam flow and conditions

At the boiler outlet. Absolute; choose a gauge unit to enter gauge readings.
Fuel firing rate1,445.0kg/h
Heat input from fuel (on GCV)7,471.3kW
Heat output to steam6,494.6kW
Steam to fuel ratio6.9202kg/kg
Steam enthalpy2,779.0kJ/kg
Feedwater enthalpy440.90kJ/kg

4 Forced draught fan

Combustion air for the fuel rate of step 3. Open this step in its calculator

  • Fuel firing rate at MCR: 1,445.0 kg/h from Fuel firing rate (step 3)

Air flow

20 % when the fan is sized from the boiler duty (peak load is 110 % of rating, plus wear and leakage). Default from FireCAD design practice; enter your specification's value.

Altitude (ISO 2533 standard atmosphere)

Barometric pressure entered

Resistance at MCR

Enter your specification's pressure margin, if any.

Fan and motor

From the fan maker at the duty point. Default from FireCAD design practice; enter your specification's value.
10 % for fan motors. Default from FireCAD design practice; enter your specification's value.
Design volume flow per fan (at the fan inlet)11,285m³/h
Design fan pressure336.51mmWC
Standard motor rating (IEC 60072-1 to 1000 kW, R20 series above)15.000kW
Minimum motor rating (absorbed + margin)14.224kW
Power absorbed at the design point12.931kW
Design mass flow per fan (wet air)13,039kg/h
Air density at the fan inlet1.1554kg/m³
Barometric pressure used1.0132bar

5 Induced draught fan

Flue gas for the fuel rate of step 3, at the exit gas temperature of step 2. Open this step in its calculator

  • Fuel firing rate at MCR: 1,445.0 kg/h from Fuel firing rate (step 3)
  • Gas temperature at the fan inlet: 140.00 °C from Flue gas temperature leaving the boiler (after air heater) (step 2)

Gas flow

Leakage at the air heater, casing, dust collector and ducts. Enter your design value.
20 % when the fan is sized from the boiler duty (peak load is 110 % of rating, plus wear and leakage). Default from FireCAD design practice; enter your specification's value.

Pressure

Sets the gas density at the inlet.
Enter your specification's pressure margin, if any.

Fan and motor

From the fan maker at the duty point. Default from FireCAD design practice; enter your specification's value.
10 % for fan motors. Default from FireCAD design practice; enter your specification's value.

Started on cold air at the same speed and flow the fan absorbs 21 kW, more than the 18 kW motor: start with the inlet damper or vanes closed, use a variable speed drive, or choose a motor that covers the cold start.

Design volume flow per fan (at the fan inlet)18,227m³/h
Design fan pressure254.93mmWC
Standard motor rating (IEC 60072-1)18.500kW
Minimum motor rating (absorbed + margin)17.405kW
Power absorbed at the design point15.822kW
Power with cold air at the same speed and flow21.279kW
Design mass flow per fan15,470kg/h
Gas density at the fan inlet0.84873kg/m³
Molar mass of the gas29.353kg/kmol
Absolute pressure at the fan inlet0.99325bar

Link to this workflow Start again with defaults

Highlighted results are carried into a later step. Each step is the published calculator with its own article, formula and verification; open a step to read them.

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.