Worked example
Example: Coal boiler: gas 37 kg/s 330 to 150 °C, air 33 kg/s from 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Flue gas flow (wet) | 133,200 kg/h |
| Mean specific heat of the wet flue gas | 1.0850 kJ/(kg·K) |
| Gas temperature in | 330.00 °C |
| Gas temperature out | 150.00 °C |
| Air flow (including its moisture) | 118,800 kg/h |
| Mean specific heat of the air | 1.0150 kJ/(kg·K) |
| Air temperature in | 30.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Hot air temperature out | 245.74 °C |
| Air preheater duty | 7,226.1 kW |
| Gas-side effectiveness | 60.000 % |
| X-ratio (air heat capacity ÷ gas heat capacity) | 0.83435 |
Open this example in the calculator and change any input.
Formula
\(\dot Q = \dot m_g\,c_{p,g}\,(T_{g,1} - T_{g,2}) \qquad T_{a,2} = T_{a,1} + \frac{\dot Q}{\dot m_a\,c_{p,a}}\)
\(\varepsilon_g = \frac{T_{g,1} - T_{g,2}}{T_{g,1} - T_{a,1}} \qquad X = \frac{\dot m_a\,c_{p,a}}{\dot m_g\,c_{p,g}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_g\) | flue gas flow | kg/s |
| \(c_{p,g}\) | mean specific heat of flue gas | J/(kg·K) |
| \(T_{g,1}\) | gas temperature in | K |
| \(T_{g,2}\) | gas temperature out | K |
| \(\dot m_a\) | air flow | kg/s |
| \(c_{p,a}\) | mean specific heat of air | J/(kg·K) |
| \(T_{a,1}\) | air temperature in | K |
| \(T_{a,2}\) | hot air temperature out | K |
| \(\dot Q\) | air preheater duty | W |
| \(\varepsilon_g\) | gas-side effectiveness | – |
| \(X\) | X-ratio, air heat capacity over gas heat capacity | – |
Method and standards
A first-law heat balance across the air preheater, with the gas-side effectiveness and X-ratio as defined in ASME PTC 4.3 (Air Heaters). Leakage is not corrected here; use the air heater leakage calculator for the no-leakage gas outlet temperature.
Where it is used
- Monitoring tubular and regenerative air heaters in coal, biomass and oil-fired boilers.
- Sizing a new air heater at the proposal stage, before the area is found with the LMTD.
- Checking the hot air temperature needed for coal mill drying or for wet biomass.
Common mistakes
- Using the measured gas outlet temperature of a leaking regenerative heater without correcting it: the cold leakage air makes it look better than it is.
- Using the total combustion air flow when part bypasses the heater (tempering air, seal air).
- Using one specific heat for gas and air.
Assumptions and limits
- No leakage and no heat loss from the casing; steady flow.
- Mean specific heats over the temperature ranges. Gas flow and its specific heat are on a wet basis (total gas including water vapour); the air flow includes its moisture.
- Crossed temperatures are rejected: the gas cannot leave colder than the air enters, and the air cannot leave hotter than the gas enters.
References
- ASME PTC 4.3-2017 Air Heaters (gas-side effectiveness, X-ratio)
- first law heat balance
Questions and answers
How do I find the hot air temperature from an air preheater?
The heat the gas loses goes into the air. 37 kg/s of gas from 330 to 150 °C gives 7.23 MW; 33 kg/s of air entering at 30 °C leaves at 246 °C. The gas-side effectiveness is 60 % and the X-ratio 0.83.
What is the X-ratio?
The heat capacity of the air divided by that of the gas through the heater. It is below 1 because there is less air than gas; leakage, tempering air and a high moisture fuel change it, and a falling X-ratio over time points at a problem.
What is gas-side effectiveness?
The gas temperature drop over the largest possible drop (gas inlet minus air inlet). ASME PTC 4.3 uses it, with leakage-corrected gas outlet temperature, to track air heater performance.
Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.