Worked example
Example: Tubular APH. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas in | 340.00 °C |
| Gas out | 150.00 °C |
| Air in | 30.000 °C |
| Air out | 280.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| X-ratio (ṁc_p)air/(ṁc_p)gas | 0.76000 |
| Gas-side effectiveness | 61.290 % |
| Air-side effectiveness | 80.645 % |
Open this example in the calculator and change any input.
Formula
\(X = \frac{T_{g,in} - T_{g,out}}{T_{a,out} - T_{a,in}}, \quad \varepsilon_g = \frac{T_{g,in} - T_{g,out}}{T_{g,in} - T_{a,in}}, \quad \varepsilon_a = \frac{T_{a,out} - T_{a,in}}{T_{g,in} - T_{a,in}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_{g,in}\) | Gas in | K |
| \(T_{g,out}\) | Gas out | K |
| \(T_{a,in}\) | Air in | K |
| \(T_{a,out}\) | Air out | K |
| \(X\) | X-ratio (ṁc_p)air/(ṁc_p)gas | - |
| \(\varepsilon_g\) | Gas-side effectiveness | - |
| \(\varepsilon_a\) | Air-side effectiveness | - |
Method and standards
Definitions from an energy balance with no leakage: the X-ratio equals the ratio of air to gas heat capacity rates because the heat the gas gives up is the heat the air takes. Both effectivenesses are referred to the gas-in to air-in span.
Where it is used
- Air heater performance tests.
- Fouling and leakage monitoring.
Common mistakes
- Leakage-diluted gas temperature used.
Assumptions and limits
- Constant specific heats; no leakage. With air leaking into the gas the measured gas outlet is low, which makes the X-ratio from temperatures read high; correct the gas outlet temperature for leakage first.
- Temperatures that cross (gas out below air in, or air out above gas in) are rejected: each effectiveness must stay at or below 1.
References
- Energy balance definitions: X = (T_g,in − T_g,out)/(T_a,out − T_a,in); effectiveness on the gas-in to air-in span
Questions and answers
What does a low X-ratio mean?
Less air than gas heat capacity: the air heats a lot but the gas cools less.
Why correct for leakage?
Leaked air dilutes and cools the gas without heat transfer.
Typical gas-side effectiveness?
Around 60–75 % for regenerative air heaters.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.