Worked example
Example: 70 bar drum. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Drum pressure (absolute) | 70.000 bar |
| Water out at full load | 250.00 °C |
| Water out at part load | 265.00 °C |
| Minimum approach wanted | 15.000 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Saturation temperature | 285.83 °C |
| Approach at full load | 35.830 K |
| Approach at part load | 20.830 K |
Open this example in the calculator and change any input.
Formula
\(\Delta T_{100} = T_{sat}(p_d) - T_{w,100}, \quad \Delta T_\lambda = T_{sat}(p_d) - T_{w,\lambda}\)
A warning appears when the smaller approach is below \(\Delta T_{min}\), and when it is zero or less (the economiser steams).
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p_d\) | Drum pressure (absolute) | Pa |
| \(T_{w,100}\) | Water out at full load | K |
| \(T_{w,\lambda}\) | Water out at part load | K |
| \(\Delta T_{min}\) | Minimum approach wanted | K |
| \(T_{sat}\) | Saturation temperature | K |
| \(\Delta T_{100}\) | Approach at full load | K |
| \(\Delta T_\lambda\) | Approach at part load | K |
Method and standards
The approach is the saturation temperature at drum pressure (IAPWS-IF97) minus the water outlet temperature, at full and at part load.
Where it is used
- Economiser design checks.
- Low-load operation reviews.
Common mistakes
- Gauge pressure for T_sat.
Assumptions and limits
- Steady state. The part-load water outlet temperature is your input; the calculator has no part-load model.
- Drum pressure is used; the economiser outlet runs a little higher, so the approach shown is slightly conservative (smaller).
References
- Saturation temperature from IAPWS-IF97; approach to saturation = saturation temperature at drum pressure minus water outlet temperature (definition)
Questions and answers
Why does the approach shrink at part load?
Gas-to-water ratio rises as water flow falls, so water leaves closer to saturation.
Why avoid steaming?
Steam pockets cause flow instability and water hammer in non-steaming designs.
Use drum or economiser outlet pressure?
Economiser outlet; the drum pressure plus line losses is close enough for a check.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.