FireCADCalc

Economiser Steaming Margin (Approach to Saturation)

Approach of the economiser water outlet temperature to saturation at drum pressure (IF97) at full and part load, and whether the economiser may steam.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Economiser and air preheater

Inputs

Examples: 70 bar drumSteaming at low load

Results

Saturation temperature285.83°C
Approach at full load35.830K
Approach at part load20.830K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 70 bar drum. The inputs, in the units selected above:

InputValue
Drum pressure (absolute)70.000 bar
Water out at full load250.00 °C
Water out at part load265.00 °C
Minimum approach wanted15.000 K

Applying the formula below gives:

ResultValue
Saturation temperature285.83 °C
Approach at full load35.830 K
Approach at part load20.830 K

Open this example in the calculator and change any input.

Formula

\(\Delta T_{100} = T_{sat}(p_d) - T_{w,100}, \quad \Delta T_\lambda = T_{sat}(p_d) - T_{w,\lambda}\)

A warning appears when the smaller approach is below \(\Delta T_{min}\), and when it is zero or less (the economiser steams).

Variables

Symbol Meaning SI unit
\(p_d\) Drum pressure (absolute) Pa
\(T_{w,100}\) Water out at full load K
\(T_{w,\lambda}\) Water out at part load K
\(\Delta T_{min}\) Minimum approach wanted K
\(T_{sat}\) Saturation temperature K
\(\Delta T_{100}\) Approach at full load K
\(\Delta T_\lambda\) Approach at part load K

Method and standards

The approach is the saturation temperature at drum pressure (IAPWS-IF97) minus the water outlet temperature, at full and at part load.

Where it is used

  • Economiser design checks.
  • Low-load operation reviews.

Common mistakes

  • Gauge pressure for T_sat.

Assumptions and limits

  • Steady state. The part-load water outlet temperature is your input; the calculator has no part-load model.
  • Drum pressure is used; the economiser outlet runs a little higher, so the approach shown is slightly conservative (smaller).

References

  • Saturation temperature from IAPWS-IF97; approach to saturation = saturation temperature at drum pressure minus water outlet temperature (definition)

Questions and answers

Why does the approach shrink at part load?

Gas-to-water ratio rises as water flow falls, so water leaves closer to saturation.

Why avoid steaming?

Steam pockets cause flow instability and water hammer in non-steaming designs.

Use drum or economiser outlet pressure?

Economiser outlet; the drum pressure plus line losses is close enough for a check.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.