Fire-Tube or Waste-Heat Boiler: Gas Outlet Temperature

Gas outlet temperature, duty and tube length for a target outlet of a fire-tube or waste-heat boiler pass (Dittus–Boelter convection plus non-luminous gas radiation, constant water temperature).

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: WHB pass 800 °C gasShell boiler second passWHB pass, radiation left out

From the flue gas analysis on the wet basis; about 0.18 for natural gas, 0.10 to 0.12 for oil, 0.06 to 0.10 for coal. Enter 0 for both gases to leave radiation out.
Wet basis; about 0.09 for natural gas, 0.12 to 0.14 for oil and coal.

Results

Gas radiation is Ganapathy's non-luminous estimate (CO₂ and H₂O, beam length equal to the tube bore, gas near atmospheric pressure); soot or ash would add luminous radiation. Fouling lowers both coefficients in service.

Reynolds number36,261
Convective coefficient (Dittus–Boelter, cooling)91.717W/(m²·K)
Non-luminous radiation coefficient at the gas inlet6.3986W/(m²·K)
Non-luminous radiation coefficient at the gas outlet2.4144W/(m²·K)
Gas outlet temperature331.22°C
Duty2,995.0kW
Tube length for the target outlet7.8516m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: WHB pass 800 °C gas. The inputs, in the units selected above:

InputValue
Gas flow (all tubes)20.000 t/h
Tubes in the pass120.00 -
Tube inside diameter50.800 mm
Tube length5.0000 m
Gas inlet temperature800.00 °C
Water (saturation) temperature184.00 °C
Target gas outlet temperature250.00 °C
Gas specific heat1.1500 kJ/(kg·K)
Gas viscosity (mean)3.2000e-05 Pa·s
Gas thermal conductivity (mean)0.050000 W/(m·K)
Water vapour in the gas, volume fraction (= partial pressure, atm)12.000 %
CO₂ + SO₂ in the gas, volume fraction (= partial pressure, atm)10.000 %

Applying the formula below gives:

ResultValue
Reynolds number36,261
Convective coefficient (Dittus–Boelter, cooling)91.717 W/(m²·K)
Non-luminous radiation coefficient at the gas inlet6.3986 W/(m²·K)
Non-luminous radiation coefficient at the gas outlet2.4144 W/(m²·K)
Gas outlet temperature331.22 °C
Duty2,995.0 kW
Tube length for the target outlet7.8516 m

Open this example in the calculator and change any input.

Formula

\(Nu = \frac{h_c d_i}{k} = 0.023 Re^{0.8} Pr^{0.3}, \quad h_N = \sigma \varepsilon_g \frac{T^4 - T_s^4}{T - T_s}\)

\(\varepsilon_g = 0.9\left(1 - e^{-K d_i}\right), \quad K = \frac{(0.8 + 1.6 p_w)(1 - 0.38\,T/1000)(p_c + p_w)}{\sqrt{(p_c + p_w) d_i}}\)

\(\dot m_1 c_p \frac{dT}{dx} = -(h_c + h_N)\,\pi d_i (T - T_s), \quad L_t = \frac{\dot m_1 c_p}{\pi d_i}\int_{T_t}^{T_{in}} \frac{dT}{(h_c + h_N)(T - T_s)}\)

Variables

Symbol Meaning SI unit
\(\dot m_g\) Gas flow (all tubes) kg/s
\(\dot m_1\) Gas flow per tube, \(\dot m_g/n\) kg/s
\(n\) Tubes in the pass -
\(d_i\) Tube inside diameter, also the radiation beam length m
\(L\) Tube length m
\(x\) Distance along the tube m
\(T\) Local gas temperature K
\(T_{in}\) Gas inlet temperature K
\(T_s\) Water (saturation) temperature, taken as the wall temperature K
\(T_{target}\) Target gas outlet temperature (\(T_t\) in the formula) K
\(c_p\) Gas specific heat J/(kg·K)
\(\mu\) Gas viscosity (mean) Pa·s
\(k\) Gas thermal conductivity (mean) W/(m·K)
\(p_w\) Water vapour in the gas, volume fraction (partial pressure in atm) -
\(p_c\) CO₂ + SO₂ in the gas, volume fraction (partial pressure in atm) -
\(K\) Attenuation factor of the gas 1/m
\(\varepsilon_g\) Gas emissivity -
\(\sigma\) Stefan–Boltzmann constant W/(m²·K⁴)
\(Re\) Reynolds number -
\(Pr\) Prandtl number -
\(Nu\) Nusselt number -
\(h_c\) Convective coefficient (Dittus–Boelter, cooling) W/(m²·K)
\(h_N\) Non-luminous radiation coefficient W/(m²·K)
\(h_{N,in}\) \(h_N\) at the gas inlet W/(m²·K)
\(h_{N,out}\) \(h_N\) at the gas outlet W/(m²·K)
\(T_{out}\) Gas outlet temperature K
\(\dot Q\) Duty W
\(L_t\) Tube length for the target outlet m

Method and standards

Dittus–Boelter convection inside the tubes plus non-luminous radiation from the CO₂ and H₂O in the gas, by Ganapathy's equations (Industrial Boilers and Heat Recovery Steam Generators, 2003, Q8.07b, Eqs. 26, 28a and 28b), with the beam length equal to the tube bore as Ganapathy gives for fire-tube boilers. The radiation coefficient changes with the gas temperature, so the energy balance is integrated along the tube with the wall at the water saturation temperature.

Where it is used

  • Fire-tube and waste-heat boiler design.
  • Exit temperature checks.

Common mistakes

  • Total gas flow used per tube.
  • Leaving out gas radiation at high inlet temperatures: it can be 5–15 % of the convective coefficient in the first pass.

Assumptions and limits

  • Turbulent flow; constant convective properties.
  • Non-luminous radiation only. The gas is taken near atmospheric pressure, so the volume fractions equal the partial pressures in atm. Soot or ash would add luminous radiation, which is not included. Enter 0 for both gas fractions to see convection alone.
  • Wall at the water saturation temperature; tube-wall, scale and soot resistances are neglected.

References

  • Dittus–Boelter Nu = 0.023 Re^0.8 Pr^0.3 (cooling); constant wall temperature T_out = T_s + (T_in − T_s) e^{−NTU} (Incropera); non-luminous gas radiation
  • Ganapathy
  • Industrial Boilers and HRSGs (2003)
  • Q8.07b
  • Eqs. 26
  • 28a
  • 28b

Questions and answers

Why constant water temperature?

The water side boils at saturation, so the tube wall stays near T_sat.

Where do gas properties come from?

Mean values at the average gas temperature; flue gas is close to air with more water vapour.

Longer tubes?

Exit temperature approaches the water temperature exponentially: the last degrees cost the most length.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.