Worked example
Example: 520 t/h, 42 bar(a) 330 °C to 39 bar(a) 540 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reheat steam flow | 520.00 t/h |
| Cold reheat pressure (absolute) | 42.000 bar |
| Cold reheat temperature | 330.00 °C |
| Hot reheat pressure (absolute) | 39.000 bar |
| Hot reheat temperature | 540.00 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reheater duty | 72.399 MW |
| Enthalpy rise | 501.23 kJ/kg |
| Pressure drop, share of inlet pressure | 7.1429 % |
| Cold reheat enthalpy | 3,037.1 kJ/kg |
| Hot reheat enthalpy | 3,538.3 kJ/kg |
Open this example in the calculator and change any input.
Formula
\(\dot Q_{rh} = \dot m_{rh}\,(h_{hrh} - h_{crh}) \qquad \frac{\Delta p}{p} = \frac{p_{crh} - p_{hrh}}{p_{crh}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\dot m_{rh}\) | reheat steam flow | kg/s |
| \(p_{crh}\) | cold reheat pressure | Pa |
| \(T_{crh}\) | cold reheat temperature | K |
| \(p_{hrh}\) | hot reheat pressure | Pa |
| \(T_{hrh}\) | hot reheat temperature | K |
| \(\dot Q_{rh}\) | reheater duty | W |
| \(\Delta h\) | enthalpy rise | J/kg |
| \(\Delta p / p\) | pressure drop share | – |
| \(h_{crh}\) | cold reheat enthalpy | J/kg |
| \(h_{hrh}\) | hot reheat enthalpy | J/kg |
Method and standards
Steam-side energy balance with IAPWS-IF97 superheated steam enthalpies.
Where it is used
- Utility boiler heat balance.
- Performance tests.
- Reheater surface checks.
Common mistakes
- Using main steam flow (reheat flow is lower by extractions and leakages).
- Forgetting spray water.
- Mixing gauge and absolute pressures.
Assumptions and limits
- Steady state; flow includes any spray added before the reheater. The duty then treats the spray as if it entered at the cold reheat enthalpy; spray water injected at feedwater enthalpy needs the extra heat m_spray (h_crh − h_spray) added.
- A note appears when the pressure drop is above 10 % of the cold reheat pressure.
References
- IAPWS-IF97
Questions and answers
What does a reheater take for 520 t/h from 42 bar 330 °C to 39 bar 540 °C?
72.4 MW: 501 kJ/kg on a 7.1 % pressure drop.
Why does reheater pressure drop matter?
Every bar lost lowers the work of the IP and LP turbine.
Is reheat spray included?
Add spray water to the flow if it is injected before the reheater.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.