Worked example
Example: Air at 50 °C, 50 mm, 2 m/s, 30 K, h 25. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluid | Air (dry) |
| Fluid temperature (film) | 50.000 °C |
| Pressure (absolute) | 1.0132 bar |
| Characteristic length | 50.000 mm |
| Velocity | 2.0000 m/s |
| Temperature difference (for Gr) | 30.000 K |
| Convection coefficient (for Nu) | 25.000 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reynolds number v L/ν | 5,595.5 |
| Prandtl number | 0.73717 |
| Grashof number g β ΔT L³/ν² | 356,303 |
| Rayleigh number Gr Pr | 262,656 |
| Péclet number Re Pr | 4,124.8 |
| Nusselt number h L/k | 46.908 |
Open this example in the calculator and change any input.
Formula
\(Re = \frac{vL}{\nu}, \quad Pr = \frac{c_p\mu}{k}, \quad Gr = \frac{g\beta\Delta T L^3}{\nu^2}, \quad Ra = Gr\,Pr, \quad Nu = \frac{hL}{k}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{fluid}\) | Fluid | - |
| \(T\) | Fluid temperature (film) | K |
| \(p\) | Pressure (absolute) | Pa |
| \(L\) | Characteristic length | m |
| \(v\) | Velocity | m/s |
| \(\Delta T\) | Temperature difference (for Gr) | K |
| \(h\) | Convection coefficient (for Nu) | W/(m²·K) |
| \(Re\) | Reynolds number v L/ν | - |
| \(Pr\) | Prandtl number | - |
| \(Gr\) | Grashof number g β ΔT L³/ν² | - |
| \(Ra\) | Rayleigh number Gr Pr | - |
| \(Pe\) | Péclet number Re Pr | - |
| \(Nu\) | Nusselt number h L/k | - |
Method and standards
Definitions.
Where it is used
- Choosing correlations.
- Heat transfer examinations.
Common mistakes
- Wrong characteristic length.
- Properties at the wrong temperature.
Assumptions and limits
- Single-phase fluid. Where the water expansion coefficient cannot be found (within 0.5 K of saturation or freezing) Gr and Ra are not shown.
References
- Definitions (Incropera, DeWitt, Bergman and Lavine, Fundamentals of Heat and Mass Transfer)
- Air from NIST Shomate
- Sutherland and Eucken (engine); water from IAPWS-IF97 and the IAPWS 2008/2011 transport releases
Questions and answers
What is Pr for air and water at 50 °C?
About 0.74 for air with these property models (handbooks give 0.70) and 3.6 for water.
When is natural convection important?
When Gr/Re² is near or above 1.
What is the Péclet number?
Re × Pr: advection against conduction.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.