Worked example
Example: Air 10 m/s over 1 m at 60 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fluid | Air (dry) |
| Free-stream velocity | 10.000 m/s |
| Plate length in the flow direction | 1.0000 m |
| Surface temperature | 60.000 °C |
| Fluid temperature | 20.000 °C |
| Pressure (absolute) | 1.0132 bar |
| Boundary layer | Laminar from the leading edge, transition at Re 5 × 10⁵ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reynolds number | 591,470 |
| Average Nusselt number | 598.64 |
| Average convection coefficient | 15.566 W/(m²·K) |
| Heat flux | 622.65 W/m² |
Open this example in the calculator and change any input.
Formula
\(\overline{Nu}_L = 0.664 Re_L^{1/2} Pr^{1/3}\ (\text{laminar}), \quad \overline{Nu}_L = (0.037 Re_L^{4/5} - 871) Pr^{1/3}\ (\text{mixed}), \quad \overline{Nu}_L = 0.037 Re_L^{4/5} Pr^{1/3}\ (\text{turbulent from the leading edge})\) \(Re_L = \frac{u_\infty L}{\nu}, \quad \bar h = \frac{\overline{Nu}_L k}{L}, \quad q = \bar h (T_s - T_\infty)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{fluid}\) | Fluid | - |
| \(u_\infty\) | Free-stream velocity | m/s |
| \(L\) | Plate length in the flow direction | m |
| \(T_s\) | Surface temperature | K |
| \(T_\infty\) | Fluid temperature | K |
| \(p\) | Pressure (absolute) | Pa |
| \(\text{boundary layer}\) | Boundary layer (laminar with transition, or tripped turbulent) | - |
| \(Re_L\) | Reynolds number | - |
| \(Nu_L\) | Average Nusselt number | - |
| \(\bar h\) | Average convection coefficient | W/(m²·K) |
| \(q''\) | Heat flux | W/m² |
Method and standards
Boundary layer correlations.
Where it is used
- Air-cooled panels and fins.
- Heat transfer examinations.
Common mistakes
- Properties at free-stream temperature.
- Ignoring transition.
Assumptions and limits
- Smooth isothermal plate, Pr 0.6–60 (flagged outside), Re up to about 10⁸ (flagged above).
- Properties at the film temperature (T_s + T_∞)/2.
- Choose a tripped (fully turbulent) boundary layer when a leading-edge disturbance makes the flow turbulent from the start.
- Single-phase: a water surface at or above saturation (boiling) is flagged.
References
- Incropera
- DeWitt
- Bergman and Lavine
- Fundamentals of Heat and Mass Transfer
- ch. 7 (Nu = 0.664 Re^½ Pr^⅓ laminar; (0.037 Re^0.8 − 871) Pr^⅓ mixed, Re_c = 5 × 10⁵)
- Air from NIST Shomate
- Sutherland and Eucken (engine); water from IAPWS-IF97 and the IAPWS 2008/2011 transport releases
Questions and answers
Air at 10 m/s over a 1 m plate at 60 °C?
Re about 5.9 × 10⁵ (mixed): h about 16 W/(m²·K).
Where is transition?
At Re about 5 × 10⁵ for a smooth plate; disturbances trip it earlier.
Is it valid for water?
Yes, for Pr from 0.6 to 60.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.