Worked example
Example: 1 atm, 10 K. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure (absolute) | 1.0132 bar |
| Wall superheat T_w − T_sat | 10.000 K |
| Surface–fluid constant | 0.013000 - |
| Prandtl exponent (1 for water) | 1.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat flux | 139.72 kW/m² |
| Boiling coefficient | 13,972 W/(m²·K) |
| Critical heat flux, Zuber–Lienhard (C = 0.149) | 1,260.7 kW/m² |
Open this example in the calculator and change any input.
Formula
\(q = \mu_l h_{fg}\left[\frac{g(\rho_l - \rho_v)}{\sigma}\right]^{1/2}\left(\frac{c_{p,l}\Delta T_e}{C_{sf} h_{fg} Pr_l^n}\right)^3, \quad h = \frac{q}{\Delta T_e}\)
\(q_{max} = 0.149\, h_{fg}\, \rho_v\left[\frac{\sigma g(\rho_l - \rho_v)}{\rho_v^2}\right]^{1/4}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Pressure (absolute) | Pa |
| \(\Delta T_e\) | Wall superheat T_w − T_sat | K |
| \(C_{sf}\) | Surface–fluid constant | - |
| \(n\) | Prandtl exponent (1 for water) | - |
| \(q\) | Heat flux | W/m² |
| \(h\) | Boiling coefficient | W/(m²·K) |
| \(q_{max}\) | Critical heat flux, Zuber–Lienhard | W/m² |
| \(\mu_l\) | Saturated liquid viscosity (IAPWS 2008) | Pa·s |
| \(h_{fg}\) | Enthalpy of evaporation (IF97) | J/kg |
| \(\rho_l\) | Saturated liquid density (IF97) | kg/m³ |
| \(\rho_v\) | Saturated vapour density (IF97) | kg/m³ |
| \(\sigma\) | Surface tension (IAPWS R1-76) | N/m |
| \(c_{p,l}\) | Saturated liquid specific heat (IF97) | J/(kg·K) |
| \(Pr_l\) | Saturated liquid Prandtl number | - |
| \(g\) | Standard gravity, 9.806 65 | m/s² |
Method and standards
Rohsenow's nucleate boiling correlation with saturation properties at the pressure; critical heat flux by Zuber with Lienhard's constant 0.149 (as in the critical heat flux calculator).
Where it is used
- Evaporator and kettle reboiler checks.
- Teaching boiling regimes.
Common mistakes
- Using the surface constant of another fluid.
Assumptions and limits
- Nucleate regime only: the page gives the critical heat flux (Zuber–Lienhard, C = 0.149, for a large flat heater) and warns when q exceeds it; above it the correlation does not apply.
References
- Rohsenow (1952) q = μ_l h_fg [g(ρ_l − ρ_v)/σ]^½ [c_p ΔT/(C_sf h_fg Pr^n)]³ (Incropera); properties from IAPWS-IF97
- IAPWS 2008/2011 and IAPWS R1-76 surface tension
Questions and answers
Why the cube?
Heat flux rises steeply with superheat in nucleate boiling: small ΔT changes mean large flux changes.
What is C_sf?
A constant for the surface–fluid pair; 0.013 is a common value for water on clean metals.
Upper limit?
The critical heat flux; beyond it the wall dries out.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.