Worked example
Example: 70 bar, 150 kW/m2. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Pressure (absolute) | 70.000 bar |
| Heat flux | 150.00 kW/m² |
| Molar mass of the fluid | 18.015 kg/kmol |
| Critical pressure of the fluid | 220.64 bar |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reduced pressure p/p_c | 0.31726 |
| Boiling coefficient | 48,634 W/(m²·K) |
| Wall superheat | 3.0843 K |
Open this example in the calculator and change any input.
Formula
\(p_r = \frac{p}{p_c}, \quad h = 55\,p_r^{0.12}(-\log_{10} p_r)^{-0.55} M^{-0.5} q^{0.67}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(p\) | Pressure (absolute) | Pa |
| \(q\) | Heat flux | W/m² |
| \(M\) | Molar mass of the fluid | kg/kmol |
| \(R_p\) | surface roughness (taken as 1 µm) | µm |
| \(p_c\) | Critical pressure of the fluid (water 22.064 MPa) | Pa |
| \(p_r\) | Reduced pressure p/p_c | - |
| \(h\) | Boiling coefficient | W/(m²·K) |
| \(\Delta T_{sat}\) | Wall superheat | K |
Method and standards
Cooper (1984) pool boiling correlation. Its full form has the exponent of p_r as 0.12 − 0.2 log₁₀ R_p, with R_p the surface roughness in µm; here R_p = 1 µm, so the exponent is 0.12.
Where it is used
- Evaporator and water-wall tube temperatures.
Common mistakes
- Heat flux in kW/m² in the formula.
Assumptions and limits
- Nucleate regime, below CHF. The heat flux is not checked against the critical heat flux: check it with the Zuber CHF calculator.
- Surface roughness about 1 µm (commercial tubes).
- Pressure below the fluid's critical pressure; defaults are for water.
References
- Cooper (1984)
- h = 55 p_r^0.12 (−log₁₀ p_r)^−0.55 M^−0.5 q^0.67 (W/m²K, q in W/m²); p_c entered (water 22.064 MPa, IAPWS-IF97)
Questions and answers
Why does h rise with pressure?
Bubbles nucleate more readily as the fluid approaches its critical point.
Is this pool or flow boiling?
Pool; flow boiling adds a convective part (Chen-type methods).
Why is the water-side resistance small?
Boiling coefficients are tens of kW/m²K, far above the gas side.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.