Worked example
Example: Furnace tube: 250 kW/m², 6 mm wall, k 40, E 190 GPa, alpha 13e-6, nu 0.3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Heat flux through the wall | 250.00 kW/m² |
| Wall thickness | 6.0000 mm |
| Wall thermal conductivity | 40.000 W/(m·K) |
| Modulus of elasticity at metal temperature | 190,000 MPa |
| Thermal expansion coefficient | 13.000 µm/(m·K) |
| Poisson's ratio | 0.30000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thermal stress at the surfaces (compressive on the heated side, tensile on the cooled side) | 66.161 MPa |
| Temperature difference across the wall | 37.500 K |
Open this example in the calculator and change any input.
Formula
\(\Delta T = \frac{q''\,t}{k} \qquad \sigma_t = \frac{E\,\alpha\,\Delta T}{2\,(1 - \nu)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(q''\) | heat flux | W/m² |
| \(t\) | wall thickness | m |
| \(k\) | conductivity | W/(m·K) |
| \(E\) | modulus of elasticity | Pa |
| \(\alpha\) | thermal expansion coefficient | 1/K |
| \(\nu\) | Poisson's ratio | – |
| \(\sigma_t\) | thermal stress at the surfaces (compressive on the heated side, tensile on the cooled side) | Pa |
| \(\Delta T\) | temperature difference across the wall | K |
Method and standards
Linear temperature gradient through a thin wall restrained against bending, giving equal and opposite surface stresses (Timoshenko and Goodier).
Where it is used
- Checking heat flux limits for thick tubes and shell furnaces.
- Start-up rate limits for drums and headers.
- Explaining thermal fatigue cracks.
Common mistakes
- Using room-temperature E for hot metal.
- Ignoring thickness: the stress grows with it.
- Comparing thermal stress alone with the allowable primary stress.
Assumptions and limits
- Thin wall, linear gradient, elastic material; no stress concentration at holes.
- For thick drums and headers the logarithmic temperature profile changes the surface stresses: use the thick cylinder thermal stress calculator there.
References
- Thermal stress of a thin wall with a linear temperature gradient (Timoshenko and Goodier, Theory of Elasticity)
Questions and answers
How large is the thermal stress in a furnace tube?
250 kW/m² through a 6 mm wall with k = 40 W/(m·K) is a 37.5 K difference; with E = 190 GPa, α = 13 × 10⁻⁶/K and ν = 0.3 the stress at the surfaces is 66 MPa.
Why do thick walls crack first?
The temperature difference grows with thickness, so drums, headers and shell boiler furnaces carry far more thermal stress, especially during fast start-ups.
Is it added to the pressure stress?
Yes, as a secondary stress; the code you design to sets how they combine and what fatigue life follows.
Method and article reviewed by FireCAD engineering on 11 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.