Duct Acoustic Standing-Wave Frequencies vs Vortex Shedding

Transverse acoustic standing-wave frequencies across a gas duct from its width and the gas speed of sound, and their ratio to a vortex-shedding frequency.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoilerEconomiser and air preheater

Inputs

Examples: 6 m duct at 400 °CAir heater duct

Results

Shedding within 20 % of acoustic mode 2: risk of acoustic resonance (loud tone, baffle damage).

Speed of sound514.89m/s
First mode42.908Hz
Second mode85.816Hz
Third mode128.72Hz
Shedding to first-mode ratio1.8645

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 6 m duct at 400 °C. The inputs, in the units selected above:

InputValue
Duct width (across the tubes, along the shedding direction)6.0000 m
Gas temperature400.00 °C
Ratio of specific heats1.3500 -
Gas molar mass28.500 kg/kmol
Vortex-shedding frequency80.000 Hz

Applying the formula below gives:

ResultValue
Speed of sound514.89 m/s
First mode42.908 Hz
Second mode85.816 Hz
Third mode128.72 Hz
Shedding to first-mode ratio1.8645

Open this example in the calculator and change any input.

Formula

\(c = \sqrt{\frac{\gamma R T}{M}}, \quad f_n = \frac{n c}{2W}\)

Variables

Symbol Meaning SI unit
\(W\) Duct width (across the tubes, along the shedding direction) m
\(T\) Gas temperature K
\(\gamma\) Ratio of specific heats -
\(M\) Gas molar mass kg/kmol
\(f_v\) Vortex-shedding frequency 1/s
\(c\) Speed of sound m/s
\(f_1\) First mode 1/s
\(f_2\) Second mode 1/s
\(f_3\) Third mode 1/s
\(f_v/f_1\) Shedding to first-mode ratio -

Method and standards

Transverse standing waves across the duct width: the \(n\)-th mode has \(n\) half wavelengths across \(W\), at the ideal-gas speed of sound. The calculator warns when the shedding frequency is within 20 % of any of the first five modes, a common screening band; the first three modes are shown.

Where it is used

  • Economiser, air heater and convection bank checks.

Common mistakes

  • Width taken along the flow.

Assumptions and limits

  • Rigid duct walls.
  • Free-gas speed of sound: in a dense tube bank the effective speed of sound is lower (by about \(1/\sqrt{1 + \sigma}\) with \(\sigma\) the bank solidity), so the true mode frequencies are somewhat lower than shown.

References

  • Transverse standing waves f_n = n c/(2W)
  • c = √(γRT/M); Blevins
  • Flow-Induced Vibration
  • 2nd ed. (Van Nostrand Reinhold, 1990); Eisinger
  • papers on tube-bank acoustic resonance

Questions and answers

Why do boiler banks 'sing'?

Vortex shedding locks onto a transverse acoustic mode of the duct and pumps sound energy.

Cure?

Anti-vibration baffles parallel to the flow split the duct width and raise the acoustic frequencies.

Which temperature?

The local gas temperature in the bank; modes shift as load changes.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.