Worked example
Example: Gas bank. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tube natural frequency | 60.000 Hz |
| Tube outside diameter | 50.800 mm |
| Mass per metre (with added mass) | 4.0000 kg/m |
| Damping ratio | 1.0000 % |
| Fluid density | 0.60000 kg/m³ |
| Connors constant | 3.3000 - |
| Actual gap velocity | 12.000 m/s |
Applying the formula below gives:
| Result | Value |
|---|---|
| Log decrement 2πζ | 0.062832 |
| Critical gap velocity | 128.15 m/s |
| Velocity ratio | 9.3642 % |
Open this example in the calculator and change any input.
Formula
\(v_c = K f_n d\sqrt{\frac{m\,\delta}{\rho d^2}}, \quad \delta = 2\pi\zeta\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(f_n\) | Tube natural frequency | 1/s |
| \(d\) | Tube outside diameter | m |
| \(m\) | Mass per metre (with added mass) | kg/m |
| \(\zeta\) | Damping ratio | - |
| \(\rho\) | Fluid density | kg/m³ |
| \(K\) | Connors constant | - |
| \(v_g\) | Actual gap velocity | m/s |
| \(\delta\) | Log decrement 2πζ | - |
| \(v_c\) | Critical gap velocity | m/s |
| \(v_g/v_c\) | Velocity ratio | - |
Method and standards
Connors' equation for the critical gap velocity of fluid-elastic instability (Connors 1970, as given by Blevins), with the log decrement \(\delta = 2\pi\zeta\). The constant \(K\) depends on the array pattern and is your input (about 2.4–4; 3.3 is common for design). A note appears when the gap velocity exceeds half the critical value, a FireCAD screening margin; at or above the critical value instability is predicted.
Where it is used
- Tube bank vibration screening.
Common mistakes
- Approach velocity used for gap velocity.
Assumptions and limits
- Uniform cross-flow; the mass per metre must include the added mass of the fluid and the tube contents.
References
- Connors (1970) v_c/(f_n d) = K [m δ/(ρ d²)]^½ (Blevins, Flow-Induced Vibration); K by array pattern (user input)
Questions and answers
What is fluid-elastic instability?
Above a critical velocity the flow feeds energy into tube motion faster than damping removes it; amplitudes grow quickly.
Which K?
Connors' constant depends on the array; values around 2.4–4 are used, often 3.3 for design.
Gas or liquid?
Both; gas flows have low density, so the critical velocity is high, but gas velocities are high too.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.