Steam Drum Steam-Space Loading (Souders–Brown)

Allowable and actual steam velocity in a drum's steam space from the steam flow, drum pressure (IF97 densities), the Souders–Brown coefficient and the free area.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolIAPWS-IF97 (water and steam)Boiler

Inputs

Examples: 46 bar drumLow pressure overload

The plan area through which the steam rises: for a horizontal drum, the drum length times the width of the water surface at the normal level.
0.06 m/s is a FireCAD starting value for a plain steam space, not a sourced figure; with separators use the maker's figure.

Results

Loading above 100 %: risk of carry-over and poor steam purity; check separators and water level.

Water density785.52kg/m³
Steam density23.224kg/m³
Allowable steam velocity0.34376m/s
Actual steam velocity0.44854m/s
Loading130.48%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 46 bar drum. The inputs, in the units selected above:

InputValue
Steam flow60.000 t/h
Drum pressure (absolute)46.000 bar
Steam-space free area1.6000 m²
Souders–Brown coefficient0.060000 m/s

Applying the formula below gives:

ResultValue
Water density785.52 kg/m³
Steam density23.224 kg/m³
Allowable steam velocity0.34376 m/s
Actual steam velocity0.44854 m/s
Loading130.48 %

Open this example in the calculator and change any input.

Formula

\(v_{allow} = K\sqrt{\frac{\rho_l - \rho_v}{\rho_v}}, \quad v = \frac{\dot m_s}{\rho_v A}\)

Variables

Symbol Meaning SI unit
\(\dot m_s\) Steam flow kg/s
\(p_d\) Drum pressure (absolute) Pa
\(A\) Steam-space free area m²
\(K\) Souders–Brown coefficient m/s
\(\rho_l\) Water density kg/m³
\(\rho_v\) Steam density kg/m³
\(v_{allow}\) Allowable steam velocity m/s
\(v\) Actual steam velocity m/s
\(v/v_{allow}\) Loading -

Method and standards

Souders–Brown: the allowable upward steam velocity is K times the square root of the density difference over the steam density (IAPWS-IF97 saturated densities); the actual velocity is the steam volume flow over the free area. The loading is their ratio.

Where it is used

  • Drum sizing.
  • Carry-over investigations.

Common mistakes

  • Gross area used instead of free area.

Assumptions and limits

  • Saturated conditions.
  • The free area is the plan area of the water surface the steam rises through (for a horizontal drum, length times the surface width at the normal water level).
  • The coefficient K carries the result linearly; the default 0.06 m/s is a FireCAD starting value for a plain steam space, not a sourced figure. Use the drum or separator maker's value.

References

  • Souders and Brown (1934) v = K √((ρ_l − ρ_v)/ρ_v); saturated densities from IAPWS-IF97

Questions and answers

Why does loading rise at low pressure?

Steam density falls, so the same mass flow needs a higher velocity.

Primary and secondary separators?

They allow far higher loadings than a plain steam space.

Sugar ingress?

Foaming from contaminated condensate reduces the allowable loading sharply.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.