Worked example
Example: 50 um, 50 000 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Oxide thickness now | 50.000 µm |
| Parabolic rate constant at metal temperature (in the units chosen below) | 0.25000 - |
| Units of the rate constant | µm²/h |
| Further service time | 50,000 h |
| Heat flux through the tube wall | 60.000 kW/m² |
| Oxide thermal conductivity | 0.60000 W/(m·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Oxide thickness then | 122.47 µm |
| Metal temperature rise now | 5.0000 K |
| Metal temperature rise then | 12.247 K |
Open this example in the calculator and change any input.
Formula
\(x = \sqrt{x_0^2 + k_p t}, \quad \Delta T = \frac{q x}{k_{ox}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(x_0\) | Oxide thickness now | m |
| \(k_p\) | Parabolic rate constant at metal temperature, in the units chosen (µm²/h, mm²/h, cm²/s or m²/s) | m²/s |
| \([k_p]\) | Units of the rate constant | - |
| \(t\) | Further service time | s |
| \(q\) | Heat flux through the tube wall | W/m² |
| \(k_{ox}\) | Oxide thermal conductivity | W/(m·K) |
| \(x\) | Oxide thickness then | m |
| \(\Delta T_0\) | Metal temperature rise now | K |
| \(\Delta T\) | Metal temperature rise then | K |
Method and standards
Parabolic oxidation law, x² = x₀² + k_p t, with the rate constant converted to m²/s from the units chosen; the temperature rise is one-dimensional conduction through the oxide at the heat flux entered.
Where it is used
- Remaining life assessment.
- Superheater inspection planning.
Common mistakes
- Rate constant at the wrong temperature.
Assumptions and limits
- Constant metal temperature: the rate constant is held fixed although the growing oxide raises the metal temperature and so the rate (the calculation does not iterate). Re-run with a higher k_p as the tube heats up.
- The default oxide conductivity, 0.6 W/(m·K), is a FireCAD starting value, not a sourced figure; use measured or published data for your oxide.
References
- Parabolic oxidation law x² = x₀² + k_p t; conduction through the scale ΔT = q x/k (rate constant from user data)
Questions and answers
Why does oxide matter?
It insulates the tube, raising metal temperature and shortening creep life.
Where does k_p come from?
Measured oxide thickness and operating hours on your tubes, or published data for the alloy and temperature.
Exfoliation?
Thick scales spall and can block bends: another reason to track them.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.