Worked example
Example: 100 000 h at 550 °C; life at 575 °C; temperature for 200 000 h. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Temperature of the known life | 550.00 °C |
| Known time to rupture at T₁ | 100,000 h |
| Larson–Miller constant | 20.000 - |
| Another temperature | 575.00 °C |
| Target life | 200,000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Larson–Miller parameter (K, time in hours) | 20,579 |
| Equivalent life at T₂ (same stress) | 18,327 h |
| Temperature for the target life (same stress) | 540.21 °C |
Open this example in the calculator and change any input.
Formula
\(LMP = T (C + \log_{10} t_h)\)
\(t_2 = 10^{LMP / T_2 - C}\)
\(T_3 = \frac{LMP}{C + \log_{10} t_3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_1\) | temperature of the known life | K |
| \(t_1\) | known time to rupture | s |
| \(C\) | Larson–Miller constant | - |
| \(T_2\) | another temperature | K |
| \(t_3\) | target life | s |
| \(t_h\) | time in hours | h |
| \(T\) | absolute temperature | K |
| \(LMP\) | Larson–Miller parameter | K |
| \(t_2\) | equivalent life at T₂ | s |
| \(T_3\) | temperature for the target life | K |
Method and standards
The Larson–Miller parameter combines temperature and time to rupture at a given stress into one number: at constant stress, all combinations with the same LMP give rupture.
Where it is used
- Judging the effect of overheating on superheater and reheater tubes.
- Comparing operating temperatures for life.
- Accelerated creep test planning.
Common mistakes
- Using °C instead of kelvin.
- Using time in seconds instead of hours.
- Comparing at different stresses.
Assumptions and limits
- Same stress; C from material data; no oxidation or wall thinning.
- Stress is not an input and no safety factor is applied: the results compare temperature and time at one stress. They are not a remaining-life assessment of boiler tubes, which needs the material's creep-rupture data at the actual stress, wall thickness measurements and inspection.
References
- Larson and Miller (1952)
Questions and answers
If a tube lasts 100 000 h at 550 °C, how long at 575 °C at the same stress?
About 18 300 h with C = 20: a 25 K rise cuts creep life by about 80 %.
What temperature gives 200 000 h?
About 540 °C in the same example.
What constant C should I use?
About 20 for many steels; fit it to creep-rupture data for the specific alloy where available.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.