Worked example
Example: E-glass/epoxy 55 %. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fibre volume fraction | 55.000 % |
| Fibre modulus | 72.000 GPa |
| Matrix modulus | 3.2000 GPa |
| Fibre density | 2,550.0 kg/m³ |
| Matrix density | 1,200.0 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Longitudinal modulus (Voigt) | 41.040 GPa |
| Transverse modulus (Reuss) | 6.7447 GPa |
| Composite density | 1,942.5 kg/m³ |
Open this example in the calculator and change any input.
Formula
\(E_L = V_f E_f + (1 - V_f)E_m, \quad \frac{1}{E_T} = \frac{V_f}{E_f} + \frac{1 - V_f}{E_m}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_f\) | Fibre volume fraction | - |
| \(E_f\) | Fibre modulus | Pa |
| \(E_m\) | Matrix modulus | Pa |
| \(\rho_f\) | Fibre density | kg/m³ |
| \(\rho_m\) | Matrix density | kg/m³ |
| \(E_L\) | Longitudinal modulus (Voigt) | Pa |
| \(E_T\) | Transverse modulus (Reuss) | Pa |
| \(\rho_c\) | Composite density | kg/m³ |
Method and standards
Rule of mixtures.
Where it is used
- FRP ducts, stacks and tanks.
- Composite repairs.
Common mistakes
- Mass instead of volume fraction.
- Using Voigt across the fibres.
Assumptions and limits
- Continuous aligned fibres, perfect bonding.
References
- Voigt (iso-strain) and Reuss (iso-stress) bounds of the rule of mixtures
Questions and answers
55 % E-glass in epoxy?
About 41.0 GPa along the fibres, 6.7 GPa across them.
Woven or random fibres?
Lower: roughly half (woven) or a third (random) of the longitudinal value.
Strength?
Strength depends on defects and fibre length; mixtures only bound stiffness well.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.