Worked example
Example: G = 8. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Value given | ASTM grain size number G |
| ASTM grain size number | 8.0000 - |
| Grains per mm² at 1× | 1,984.0 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Grain size number | 8.0000 |
| Grains per mm² at 1× | 1,984.0 |
| Grains per square inch at 100× | 128.00 |
| Mean grain diameter 1/√N_A | 22.451 µm |
Open this example in the calculator and change any input.
Formula
\(N_{100} = 2^{G-1}, \quad N_A = 15.50 \times 2^{G-1}, \quad \bar d = \frac{1}{\sqrt{N_A}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{given}\) | Value given | - |
| \(G\) | ASTM grain size number | - |
| \(N_A\) | Grains per mm² at 1× | - |
| \(N_{100}\) | Grains per square inch at 100× | - |
| \(\bar d\) | Mean grain diameter 1/√N_A | m |
Method and standards
ASTM E112 definition.
Where it is used
- Metallography reports.
- Weld and heat treatment checks.
Common mistakes
- Magnification mixed up.
- Different diameter conventions.
Assumptions and limits
- Equiaxed grains.
- The mean diameter is 1/√N_A (about 22.5 µm at G 8); the ASTM E112 mean lineal intercept is smaller (about 20 µm at G 8). Use the convention your Hall–Petch data were fitted with.
References
- ASTM E112 definition N = 2^(G−1) grains per in² at 100×; ×15.50 for grains per mm² at 1×
Questions and answers
G = 8?
About 1984 grains per mm², mean size about 22.5 µm.
Larger G?
Finer grains: each step halves the grain area.
Which diameter for Hall–Petch?
Use the convention your data were fitted with.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.