FireCADCalc

Fatigue Crack Growth Life (Paris Law)

Cycles for a fatigue crack to grow from an initial to a final size under a constant stress range by the Paris law, with ΔK at both sizes.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: Ferrite–pearlite steel, 1 → 20 mm at 100 MPaMartensitic steel m 2.25, 0.5 → 8 mm at 200 MPa

Always in m/cycle with ΔK in MPa√m, whatever the unit system. A constant in in/cycle with ΔK in ksi√in converts as C = C_US × 0.0254 / 1.0988^m.

Results

Constant Y; for large cracks Y changes and the integral should be done numerically. Below the threshold ΔK_th (about 2–8 MPa√m for steels) cracks do not grow. Barsom–Rolfe: C = 6.9 × 10⁻¹², m = 3 for ferrite–pearlite steels.

Cycles to grow a₀ → a_c909,670
ΔK at a₀ (MPa√m)6.2776
ΔK at a_c (MPa√m)28.074

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Ferrite–pearlite steel, 1 → 20 mm at 100 MPa. The inputs, in the units selected above:

InputValue
Paris coefficient (m/cycle, ΔK in MPa√m)6.9000e-12 -
Paris exponent3.0000 -
Geometry factor1.1200 -
Stress range100.00 MPa
Initial crack size1.0000 mm
Final (critical) crack size20.000 mm

Applying the formula below gives:

ResultValue
Cycles to grow a₀ → a_c909,670
ΔK at a₀ (MPa√m)6.2776
ΔK at a_c (MPa√m)28.074

Open this example in the calculator and change any input.

Formula

\(\frac{da}{dN} = C(\Delta K)^m, \quad \Delta K = Y\Delta\sigma\sqrt{\pi a}, \quad N = \frac{a_c^{1 - m/2} - a_0^{1 - m/2}}{(1 - m/2)C(Y\Delta\sigma\sqrt\pi)^m}\)

Variables

Symbol Meaning SI unit
\(C\) Paris coefficient (m/cycle, ΔK in MPa√m) -
\(m\) Paris exponent -
\(Y\) Geometry factor -
\(\Delta\sigma\) Stress range Pa
\(a_0\) Initial crack size m
\(a_c\) Final (critical) crack size m
\(N\) Cycles to grow a₀ → a_c -
\(\Delta K_0\) ΔK at a₀ (MPa√m) -
\(\Delta K_c\) ΔK at a_c (MPa√m) -

Method and standards

Integrated Paris law.

Where it is used

  • Inspection intervals for cracked components.
  • Damage-tolerance checks.

Common mistakes

  • Mixing units in C.
  • Ignoring the change of Y with crack size.

Assumptions and limits

  • Constant amplitude; constant Y; m ≠ 2.
  • C is a plain number for da/dN in m/cycle and ΔK in MPa√m in every unit system. Constants in in/cycle and ksi√in convert as C = C_US × 0.0254 / 1.0988^m (1 ksi√in = 1.0988 MPa√m).

References

  • Paris and Erdogan (1963); Barsom and Rolfe
  • Fracture and Fatigue Control in Structures (steel constants); Dowling
  • Mechanical Behavior of Materials
  • 4th ed. (Pearson, 2013)
  • ch. 11

Questions and answers

Why does most life go at small crack sizes?

Growth rate rises with ΔK to the power m; a small crack grows slowly, so most cycles are spent while it is small.

Where does the final crack size come from?

From fracture toughness (critical crack size) or from a leak or net-section limit.

What do the defaults represent?

A ferrite–pearlite steel with a 1 mm edge crack growing to 20 mm under a 100 MPa stress range.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.