Worked example
Example: Edge crack, steel. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Applied stress | 200.00 MPa |
| Geometry factor | 1.1200 - |
| Fracture toughness (MPa·m^½) | 50.000 - |
| Crack size (depth or half-length) | 5.0000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Stress intensity factor (MPa·m^½) | 28.074 |
| Critical crack size | 15.860 mm |
| Failure stress for the crack | 356.20 MPa |
Open this example in the calculator and change any input.
Formula
\(K_I = Y\sigma\sqrt{\pi a}, \quad a_c = \frac{1}{\pi}\left(\frac{K_{Ic}}{Y\sigma}\right)^2\)
Variables
| Symbol | Meaning | SI unit | ||
|---|---|---|---|---|
| \(\sigma\) | Applied stress | Pa | ||
| \(Y\) | Geometry factor | - | ||
| \(K_{Ic}\) | Fracture toughness (MPa·m½) | - | ||
| \(a\) | Crack size (depth or half-length) | m | ||
| \(K_I\) | Stress intensity factor (MPa·m½) | - | ||
| \(a_c\) | Critical crack size | m | ||
| \(\sigma_f\) | Failure stress for the crack | Pa |
Method and standards
LEFM.
Where it is used
- Inspection acceptance and fitness for service screening.
- Examinations.
Common mistakes
- Full crack length instead of half for centre cracks.
- Toughness at the wrong temperature.
Assumptions and limits
- Small-scale yielding: the failure stress must be well below the yield strength, which is not an input here.
- With no crack (a = 0) the failure stress is not shown.
- K_Ic and K_I are entered and shown in MPa·m^½ as their labels say; the unit lists do not convert them.
References
- K_I = Yσ√(πa); fracture when K_I = K_Ic (Irwin; linear-elastic fracture mechanics)
Questions and answers
200 MPa, edge crack, K_Ic 50 MPa·m^½?
Critical depth about 15.9 mm.
A 5 mm crack?
K about 28.1 MPa·m^½, below toughness.
Why low temperature matters?
Ferritic steel toughness drops sharply below its transition temperature.