Worked example
Example: K_t 2.5, 200 MPa, K′ 1,200 MPa, n′ 0.15. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Elastic stress concentration factor | 2.5000 - |
| Nominal stress | 200.00 MPa |
| Elastic modulus | 200.00 GPa |
| Cyclic strength coefficient | 1,200.0 MPa |
| Cyclic strain-hardening exponent | 0.15000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Notch root stress | 418.61 MPa |
| Notch root strain | 0.002986 |
| Stress concentration (actual) | 2.0931 |
| Strain concentration | 2.9861 |
Open this example in the calculator and change any input.
Formula
\(\sigma\varepsilon = \frac{(K_tS)^2}{E}, \quad \varepsilon = \frac{\sigma}{E} + \left(\frac{\sigma}{K'}\right)^{1/n'}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(K_t\) | Elastic stress concentration factor | - |
| \(S\) | Nominal stress | Pa |
| \(E\) | Elastic modulus | Pa |
| \(K'\) | Cyclic strength coefficient | Pa |
| \(n'\) | Cyclic strain-hardening exponent | - |
| \(\sigma\) | Notch root stress | Pa |
| \(\varepsilon\) | Notch root strain | - |
| \(K_\sigma\) | Stress concentration (actual) | - |
| \(K_\varepsilon\) | Strain concentration | - |
Method and standards
Neuber's rule.
Where it is used
- Low-cycle fatigue of notched parts.
- Start-up and shut-down cycles of pressure parts.
Common mistakes
- Using monotonic instead of cyclic properties.
- Applying it with yielded nominal sections.
Assumptions and limits
- Elastic nominal section; uniaxial. A warning appears when S exceeds the cyclic 0.2 % offset yield strength K'(0.002)^n'.
References
- Neuber (1961) rule with the Ramberg–Osgood cyclic curve (Dowling, Mechanical Behavior of Materials, 4th ed. (Pearson, 2013), ch. 14)
Questions and answers
Why not just K_t × S?
Once the notch root yields, the elastic answer overstates stress and understates strain; strain controls low-cycle fatigue.
Where do K' and n' come from?
From cyclic stress–strain tests; handbooks list them for common steels and aluminium alloys.
What do the defaults represent?
A notch with K_t = 2.5 under 200 MPa nominal in a steel with K' = 1,200 MPa, n' = 0.15.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.