Worked example
Example: 20,000 h at 90 °C, run at 110 °C, 80 kJ/mol. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Known life | 20,000 h |
| Temperature for the known life | 90.000 °C |
| New temperature | 110.00 °C |
| Activation energy | 80.000 kJ/mol |
Applying the formula below gives:
| Result | Value |
|---|---|
| Life at the new temperature | 5,016.4 h |
| Acceleration factor L₁/L₂ | 3.9870 |
| Temperature rise that halves life near T₁ | 9.5004 K |
Open this example in the calculator and change any input.
Formula
\(L_2 = L_1\exp\left[\frac{E_a}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right)\right], \quad \Delta T_{1/2} \approx \frac{RT_1^2\ln2}{E_a}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_1\) | Known life | s |
| \(T_1\) | Temperature for the known life | K |
| \(T_2\) | New temperature | K |
| \(E_a\) | Activation energy | J/mol |
| \(L_2\) | Life at the new temperature | s |
| \(AF\) | Acceleration factor L₁/L₂ | - |
| \(\Delta T_{1/2}\) | Temperature rise that halves life near T₁ | K |
Method and standards
Arrhenius relation.
Where it is used
- Motor and transformer insulation life.
- Elastomer seals and hoses.
Common mistakes
- Extrapolating across a change of mechanism.
- Using °C instead of kelvin.
Assumptions and limits
- Single thermally activated mechanism.
References
- Arrhenius ageing L ∝ exp(E_a/RT) (IEC 60216 principle; Montsinger's 10 K rule as a special case)
Questions and answers
Where does the 10 K rule come from?
With activation energy near 80 kJ/mol around 100 °C, a 10 K rise doubles the reaction rate and halves life.
How do I find E_a?
From ageing tests at two or more temperatures, or from the material's thermal endurance data.
What do the defaults represent?
A material good for 20,000 h at 90 °C, run at 110 °C, with E_a = 80 kJ/mol.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.