FireCADCalc

Corrosion Rate and Remaining Life from Thickness

Corrosion rate from two wall thickness readings and the time between them, in mm/y and mpy, and the remaining life down to the minimum required thickness.

Thermal power plantRefinery and petrochemicalChemical and fertiliserBoilerTank and drum

Inputs

Examples: 12.7 to 10.9 mm in 6 years, minimum 7.2 mmEconomiser tube 4.0 to 3.4 mm in 3 years, minimum 2.6Tank shell 8 to 7.6 mm in 10 years, minimum 5

From the design code calculation for pressure and structural loads.

Results

Corrosion rate (mm per year)0.30000
Corrosion rate (mils per year)11.811
Remaining life (years)12.333
Metal lost between the readings1.8000mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 12.7 to 10.9 mm in 6 years, minimum 7.2 mm. The inputs, in the units selected above:

InputValue
Earlier thickness reading (or original thickness)12.700 mm
Latest thickness reading10.900 mm
Years between the readings6.0000 -
Minimum required thickness7.2000 mm

Applying the formula below gives:

ResultValue
Corrosion rate (mm per year)0.30000
Corrosion rate (mils per year)11.811
Remaining life (years)12.333
Metal lost between the readings1.8000 mm

Open this example in the calculator and change any input.

Formula

\(CR = \frac{t_1 - t_2}{\Delta y} \qquad CR_{mpy} = \frac{CR}{0.0254} \qquad RL = \frac{t_2 - t_{min}}{CR} \qquad \Delta t = t_1 - t_2\)

Variables

Symbol Meaning SI unit
\(t_1\) earlier thickness m
\(t_2\) latest thickness m
\(\Delta y\) years between years
\(t_{min}\) minimum required thickness m
\(CR\) corrosion rate mm/y
\(CR_{mpy}\) corrosion rate mils/y
\(RL\) remaining life years
\(\Delta t\) metal lost m

Method and standards

Linear corrosion between readings at the same location; 1 mil = 0.0254 mm.

Where it is used

  • Boiler tube and drum surveys.
  • Tank and pipe inspection.
  • Planning replacements.

Common mistakes

  • Comparing readings at different spots.
  • Ignoring measurement scatter (±0.1–0.2 mm).
  • Assuming the rate stays constant after a change in service.

Assumptions and limits

  • Uniform corrosion; pitting needs other methods.
  • The remaining life has no safety factor. Inspection codes usually set the next inspection at a fraction of the remaining life (often half); follow the code that applies to the equipment.

References

  • Thickness-based corrosion rate (inspection practice)

Questions and answers

What is the rate if 12.7 mm fell to 10.9 mm in 6 years?

0.30 mm/y (11.8 mpy); with a 7.2 mm minimum, 12.3 years of life remain.

Long-term or short-term rate?

Use both, and plan on the higher.

Where does the minimum thickness come from?

From the design code calculation for pressure and structural loads.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.