Worked example
Example: 85 µm, 2 µm a year. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Value given | Thickness |
| Coating thickness | 85.000 µm |
| Coating mass per area (one side) | 610.00 - |
| Coating density | 7,140.0 kg/m³ |
| Coated area | 12.000 m² |
| Coating corrosion rate in service | 2.0000 µm/a |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thickness | 85.000 µm |
| Mass per area | 606.90 g/m² |
| Coating on the part | 7.2828 kg |
| Life to first maintenance | 42.500 a |
Open this example in the calculator and change any input.
Formula
\(m'' = \delta\rho, \quad t_L = \frac{\delta}{CR}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{given}\) | Value given | - |
| \(\delta\) | Coating thickness | m |
| \(m''\) | Coating mass per area (one side) | - |
| \(\rho\) | Coating density | kg/m³ |
| \(A\) | Coated area | m² |
| \(CR\) | Coating corrosion rate in service | m/s |
| \(m\) | Coating on the part | kg |
| \(t_L\) | Life to first maintenance | s |
Method and standards
Definitions.
Where it is used
- Structural steel and cable trays.
- Specifying galvanising.
Common mistakes
- Total vs per-side mass.
- Ignoring local corrosivity.
Assumptions and limits
- Uniform coating and corrosion. With a zero corrosion rate the life is not shown.
- The mass per area input is in g/m² as a plain number; the output mass per area can be shown in other units.
References
- Mass per area = thickness × density; life = thickness/corrosion rate
Questions and answers
85 µm of zinc?
About 607 g/m².
Life at 2 µm a year?
About 42 years before the zinc is gone in that atmosphere.
Both sides of sheet?
Sheet coating weights often quote the total for both sides; halve it per side.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.