Corrosion Rate from Polarisation Resistance (Stern–Geary)

Corrosion current density and corrosion rate of a metal from its linear polarisation resistance and Tafel slopes by the Stern–Geary equation and Faraday's law.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: Carbon steel, 120/120 mV, 2 kΩ·cm²Copper alloy 60/150 mV, 20 kΩ·cm²

Results

Equivalent weight = atomic mass / valence (iron 55.845/2 = 27.92). If Tafel slopes are unknown, B of about 26 mV (active steel) is often used. LPR suits conductive liquids; it misses localised (pitting) attack.

Stern–Geary constant (mV)26.058
Corrosion current density (µA/cm²)13.029
Corrosion rate (mm/year)0.15118

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Carbon steel, 120/120 mV, 2 kΩ·cm². The inputs, in the units selected above:

InputValue
Anodic Tafel slope (mV/decade)120.00 -
Cathodic Tafel slope (mV/decade)120.00 -
Polarisation resistance (Ω·cm²)2,000.0 -
Equivalent weight (g per equivalent)27.920 kg/kmol
Metal density7,870.0 kg/m³

Applying the formula below gives:

ResultValue
Stern–Geary constant (mV)26.058
Corrosion current density (µA/cm²)13.029
Corrosion rate (mm/year)0.15118

Open this example in the calculator and change any input.

Formula

\(B = \frac{\beta_a\beta_c}{2.303(\beta_a + \beta_c)}, \quad i_{corr} = \frac{B}{R_p}, \quad CR = \frac{i_{corr}EW}{F\rho}\)

Variables

Symbol Meaning SI unit
\(\beta_a\) Anodic Tafel slope (mV/decade) -
\(\beta_c\) Cathodic Tafel slope (mV/decade) -
\(R_p\) Polarisation resistance (Ω·cm²) -
\(EW\) Equivalent weight (g per equivalent) kg/kmol
\(\rho\) Metal density kg/m³
\(B\) Stern–Geary constant (mV) -
\(i_{corr}\) Corrosion current density (µA/cm²) -
\(CR\) Corrosion rate (mm/year) -

Method and standards

Stern–Geary and Faraday.

Where it is used

  • Cooling water and process corrosion monitoring.
  • Inhibitor trials.

Common mistakes

  • Mixing Ω and Ω·cm².
  • Using LPR in low-conductivity water.

Assumptions and limits

  • Uniform corrosion; activation control.
  • Faraday constant from CODATA (96 485.332 12 C/mol). Tafel slopes, R_p, B, i_corr and CR are entered and shown in the units named in their labels (mV/decade, Ω·cm², mV, µA/cm², mm/year), not converted by the unit lists.

References

  • Stern and Geary (1957); ASTM G59 and G102 (Faraday's-law conversion to penetration rate); Jones
  • Principles and Prevention of Corrosion
  • 2nd ed. (Prentice Hall, 1996)

Questions and answers

What is a corrosion rate of 0.1 mm/y?

Moderate for carbon steel in cooling water; many systems aim for less than 0.075 mm/y (3 mpy).

Where do Tafel slopes come from?

From a potentiodynamic scan, or literature values for the metal and environment.

What do the defaults represent?

Carbon steel with 120 mV/decade slopes and 2 kΩ·cm² polarisation resistance.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.