Worked example
Example: Magnesium, 20 years. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Mean current demand | 2.5000 A |
| Design life | 20.000 a |
| Electrochemical capacity (A·h/kg) | 1,100.0 - |
| Utilisation factor | 85.000 % |
| Net mass of one anode | 14.500 kg |
Applying the formula below gives:
| Result | Value |
|---|---|
| Total anode mass | 468.77 kg |
| Number of anodes (rounded up) | 33.000 |
Open this example in the calculator and change any input.
Formula
\(M = \frac{I_m\, t}{\varepsilon\, u}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(I_m\) | Mean current demand | A |
| \(t\) | Design life | s |
| \(\varepsilon\) | Electrochemical capacity (A·h/kg) | - |
| \(u\) | Utilisation factor | - |
| \(m_a\) | Net mass of one anode | kg |
| \(M\) | Total anode mass | kg |
| \(N\) | Number of anodes (rounded up) | - |
Method and standards
Charge balance.
Where it is used
- Buried pipes and tank bottoms.
- Condenser water boxes and intake screens.
Common mistakes
- Theoretical instead of practical capacity.
- Hours vs years.
Assumptions and limits
- Mean current over life.
References
- Anode mass M = I_m t/(ε u) (cathodic protection design practice, DNV-RP-B401 form)
Questions and answers
2.5 A for 20 years, magnesium 1100 A·h/kg, 85 % utilisation?
About 469 kg: 33 anodes of 14.5 kg.
Why utilisation below 1?
Anodes stop working before they are fully consumed.
Mean or final current?
Mean for mass; final for checking output.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.