FireCADCalc

Sacrificial Anode Mass and Number for a Design Life

Net anode mass for a mean protection current over a design life from the anode's electrochemical capacity and utilisation factor, and the number of anodes.

Thermal power plantRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Magnesium, 20 yearsZinc in seawater, 10 years

From the anode maker for the alloy and environment (zinc about 780, magnesium about 1100–1230, aluminium about 2000–2500).

Results

Also check that the anodes can deliver the initial and final currents (anode resistance), which this mass check does not cover.

Total anode mass468.77kg
Number of anodes (rounded up)33.000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Magnesium, 20 years. The inputs, in the units selected above:

InputValue
Mean current demand2.5000 A
Design life20.000 a
Electrochemical capacity (A·h/kg)1,100.0 -
Utilisation factor85.000 %
Net mass of one anode14.500 kg

Applying the formula below gives:

ResultValue
Total anode mass468.77 kg
Number of anodes (rounded up)33.000

Open this example in the calculator and change any input.

Formula

\(M = \frac{I_m\, t}{\varepsilon\, u}\)

Variables

Symbol Meaning SI unit
\(I_m\) Mean current demand A
\(t\) Design life s
\(\varepsilon\) Electrochemical capacity (A·h/kg) -
\(u\) Utilisation factor -
\(m_a\) Net mass of one anode kg
\(M\) Total anode mass kg
\(N\) Number of anodes (rounded up) -

Method and standards

Charge balance.

Where it is used

  • Buried pipes and tank bottoms.
  • Condenser water boxes and intake screens.

Common mistakes

  • Theoretical instead of practical capacity.
  • Hours vs years.

Assumptions and limits

  • Mean current over life.

References

  • Anode mass M = I_m t/(ε u) (cathodic protection design practice, DNV-RP-B401 form)

Questions and answers

2.5 A for 20 years, magnesium 1100 A·h/kg, 85 % utilisation?

About 469 kg: 33 anodes of 14.5 kg.

Why utilisation below 1?

Anodes stop working before they are fully consumed.

Mean or final current?

Mean for mass; final for checking output.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.