Worked example
Example: Steel part 600 to 100 °C in 30 °C air, h 50. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Initial temperature of the body | 600.00 °C |
| Fluid temperature | 30.000 °C |
| Temperature wanted (for the time) | 100.00 °C |
| Time (for the temperature) | 600.00 s |
| Convection coefficient | 50.000 W/(m²·K) |
| Volume of the body | 1.0000e-04 m³ |
| Surface area | 0.012000 m² |
| Density | 7,850.0 kg/m³ |
| Specific heat | 0.49000 kJ/(kg·K) |
| Conductivity of the body (for the Biot number) | 45.000 W/(m·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Biot number h L_c / k, L_c = V/A | 0.009259 |
| Time constant ρ V c_p/(h A) | 641.08 s |
| Time to reach the temperature wanted | 1,344.4 s |
| Temperature after the time given | 253.57 °C |
Open this example in the calculator and change any input.
Formula
\(\frac{T - T_\infty}{T_i - T_\infty} = e^{-t/\tau}, \quad \tau = \frac{\rho V c_p}{h A_s}, \quad Bi = \frac{h V/A_s}{k}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_i\) | Initial temperature of the body | K |
| \(T_\infty\) | Fluid temperature | K |
| \(T\) | Temperature wanted (for the time) | K |
| \(t\) | Time (for the temperature) | s |
| \(h\) | Convection coefficient | W/(m²·K) |
| \(V\) | Volume of the body | m³ |
| \(A_s\) | Surface area | m² |
| \(\rho\) | Density | kg/m³ |
| \(c_p\) | Specific heat | J/(kg·K) |
| \(k\) | Conductivity of the body (for the Biot number) | W/(m·K) |
| \(Bi\) | Biot number h L_c / k, L_c = V/A | - |
| \(\tau\) | Time constant ρ V c_p/(h A) | s |
| \(t_T\) | Time to reach the temperature wanted | s |
| \(T_t\) | Temperature after the time given | K |
Method and standards
Energy balance on a uniform-temperature body.
Where it is used
- Cooling of castings, forgings and sensors.
- Heat transfer examinations.
Common mistakes
- Ignoring the Biot check.
- Constant h assumed through large changes.
Assumptions and limits
- Uniform body temperature, constant h. Results are still given when Bi > 0.1 (with a note), but they are then approximate.
- h must include radiation where it matters: for a hot body in air (for example steel at several hundred °C) radiation dominates, so add h_r = εσ(T_s² + T_∞²)(T_s + T_∞) to the convective h.
References
- Incropera
- DeWitt
- Bergman and Lavine
- Fundamentals of Heat and Mass Transfer
- ch. 5 (lumped capacitance)
Questions and answers
A small steel part from 600 °C to 100 °C in 30 °C air (h 50)?
Time constant about 640 s; about 22 minutes.
When is lumped valid?
Biot number below 0.1: internal gradients are small.
Why is quenching in water faster?
h is hundreds of times larger, but then Bi often exceeds 0.1.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.