Worked example
Example: Ganapathy Q8.09b: 2000 °F gas, 400 °F walls, h 15 (book 1250 °F). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas temperature | 1,093.3 °C |
| Surrounding wall temperature | 204.44 °C |
| Gas-to-probe convective coefficient | 85.174 W/(m²·K) |
| Probe emissivity | 90.000 % |
| Wall emissivity | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Probe temperature | 678.71 °C |
| Radiation error (gas minus probe) | 414.62 K |
| Heat flux through the probe surface | 35.315 kW/m² |
Open this example in the calculator and change any input.
Formula
\(h_c(T_g - T_p) = \sigma\varepsilon_p\varepsilon_w\left(T_p^4 - T_w^4\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(T_g\) | Gas temperature | K |
| \(T_w\) | Surrounding wall temperature | K |
| \(h_c\) | Gas-to-probe convective coefficient | W/(m²·K) |
| \(\varepsilon_p\) | Probe emissivity | - |
| \(\varepsilon_w\) | Wall emissivity | - |
| \(T_p\) | Probe temperature | K |
| \(T_g - T_p\) | Radiation error (gas minus probe) | K |
| \(q\) | Heat flux through the probe surface | W/m² |
Method and standards
Convection–radiation balance.
Where it is used
- Furnace gas temperature measurement.
- Soot blower and probe material selection.
Common mistakes
- Taking the reading as the gas temperature.
- Ignoring low gas velocity at part load.
Assumptions and limits
- Steady state; no conduction along the probe.
- Effective emissivity ε_p ε_w as in Ganapathy. For a small probe in a large enclosure the classical exchange uses ε_p alone, which gives a larger radiation error than shown here.
References
- Ganapathy
- Industrial Boilers and Heat Recovery Steam Generators (Marcel Dekker, 2003)
- Q8.09b (soot blower lance temperature: convection–radiation balance)
Questions and answers
Why does a thermocouple read low in a furnace?
It loses heat by radiation to cooler walls; it settles where convection from the gas equals that loss, below the gas temperature.
What does Ganapathy's example give?
Gas at 2,000 °F, walls at 400 °F, h 15 Btu/(ft²·h·°F): the lance reaches about 1,250 °F; at h 5 only about 970 °F.
How can the error be reduced?
Raise h (suction pyrometer), shield the probe, or use a lower-emissivity sheath.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.