FireCADCalc

Steinhart–Hart Coefficients from Three Points

Steinhart–Hart coefficients A, B and C of a thermistor from three resistance–temperature points, and the temperature at a measured resistance.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 10 k NTC: 0, 25, 50 °C points; 5 kΩWide range −20, 40, 120 °CThree close points 20, 30, 40 °C

Calibration points

Results

Pick points spread over the range of use; the fit is exact at the three points.

Coefficient A0.001125
Coefficient B2.3472e-04
Coefficient C8.5631e-08
Temperature at the measured resistance41.580°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 k NTC: 0, 25, 50 °C points; 5 kΩ. The inputs, in the units selected above:

InputValue
Temperature 10 °C
Resistance at T₁32,650 Ω
Temperature 225.000 °C
Resistance at T₂10,000 Ω
Temperature 350.000 °C
Resistance at T₃3,603.0 Ω
Measured resistance5,000.0 Ω

Applying the formula below gives:

ResultValue
Coefficient A0.001125
Coefficient B2.3472e-04
Coefficient C8.5631e-08
Temperature at the measured resistance41.580 °C

Open this example in the calculator and change any input.

Formula

\(\frac1T = A + B \ln R + C (\ln R)^3\)

With \(L_i = \ln R_i\), \(Y_i = 1/T_i\) and \(\gamma_2 = \frac{Y_2 - Y_1}{L_2 - L_1}\), \(\gamma_3 = \frac{Y_3 - Y_1}{L_3 - L_1}\):

\(C = \frac{\gamma_3 - \gamma_2}{(L_3 - L_2)(L_1 + L_2 + L_3)}, \quad B = \gamma_2 - C\left(L_1^2 + L_1L_2 + L_2^2\right), \quad A = Y_1 - \left(B + C L_1^2\right)L_1\)

Variables

Symbol Meaning SI unit
\(T_1\) Temperature 1 K
\(R_1\) Resistance at T₁ Ω
\(T_2\) Temperature 2 K
\(R_2\) Resistance at T₂ Ω
\(T_3\) Temperature 3 K
\(R_3\) Resistance at T₃ Ω
\(R_m\) Measured resistance Ω
\(A\) Coefficient A -
\(B\) Coefficient B -
\(C\) Coefficient C -
\(T\) Temperature at the measured resistance K
\(R\) Resistance in the equation Ω
\(L_i, Y_i\) ln R_i (R in Ω) and 1/T_i -, 1/K
\(\gamma_2, \gamma_3\) Slopes between points 1–2 and 1–3 K⁻¹

Method and standards

Three linear equations in A, B and C.

Where it is used

  • Thermistor calibration.
  • Programming instruments with ABC coefficients.

Common mistakes

  • Points too close together.
  • Mixing °C and K.

Assumptions and limits

  • NTC thermistor; resistances in ohms inside the logarithms.
  • No unique fit exists when R₁R₂R₃ = 1 Ω³ (ln R₁ + ln R₂ + ln R₃ = 0); the page then asks for other points. Real thermistor points in the kΩ range are far from this.

References

  • J.S. Steinhart and S.R. Hart
  • Deep-Sea Research 15 (1968) 497

Questions and answers

Why three points?

The equation has three unknowns, A, B and C.

How accurate is it?

Typically within a few hundredths of a kelvin over 100 K.

Is the default a real thermistor?

Points typical of a 10 k NTC; use your own calibration data.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators