FireCADCalc

Linear Interpolation Calculator (Steam Tables and Data)

Value of y at x between two known points by straight-line interpolation, the way steam table and data table values are read between rows, with a warning when extrapolating.

Boiler attendant and boiler operator examinations

Inputs

Examples: Saturation temperature at 11 bar from 10 and 12 bar rowsBetween 100 and 150, at 130Extrapolation beyond the table

Results

Interpolated value183.92
Slope (y₂ − y₁) / (x₂ − x₁)4.0400
Position between the points (x − x₁) / (x₂ − x₁)0.50000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Saturation temperature at 11 bar from 10 and 12 bar rows. The inputs, in the units selected above:

InputValue
First known x10.000 -
y at x₁179.88 -
Second known x12.000 -
y at x₂187.96 -
x to interpolate at11.000 -

Applying the formula below gives:

ResultValue
Interpolated value183.92
Slope (y₂ − y₁) / (x₂ − x₁)4.0400
Position between the points (x − x₁) / (x₂ − x₁)0.50000

Open this example in the calculator and change any input.

Formula

\(y = y_1 + (x - x_1)\, \frac{y_2 - y_1}{x_2 - x_1}\)

Variables

Symbol Meaning SI unit
\(x_1\) First known x -
\(y_1\) y at x₁ -
\(x_2\) Second known x -
\(y_2\) y at x₂ -
\(x\) x to interpolate at -
\(y\) Interpolated value -
\(m\) Slope (y₂ − y₁) / (x₂ − x₁) -
\(f\) Position between the points (x − x₁) / (x₂ − x₁) -

Method and standards

Straight line through two points.

Where it is used

  • Boiler attendant examinations: steam table values between rows.
  • Reading any engineering table.
  • Data sheets.

Common mistakes

  • Swapping x and y.
  • Interpolating across a phase change.
  • Extrapolating far beyond the table.

Assumptions and limits

  • Straight line between the two points.

References

  • Linear (Lagrange first-order) interpolation

Questions and answers

What is the saturation temperature at 11 bar from rows at 10 bar (179.88 °C) and 12 bar (187.96 °C)?

183.92 °C: halfway between the rows.

Is linear interpolation accurate in steam tables?

Between close rows, yes; across wide gaps the curve bends and the error grows.

What is extrapolation?

Going beyond the two points. The calculator warns, because the straight line may not hold there.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.