FireCADCalc

Displacer Level: Buoyancy Force and Range

Buoyancy force and apparent weight of a level displacer at a level from its diameter, length and the liquid density, and the force change over the range.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 60 mm x 1 m, 5 kg, oil 850, 0.4 m coveredBoiler drum: 80 mm x 0.8 m, 8 kg, water 830 at 15 bar, steam 7.6Fully covered, 50 mm x 2 m in 1 000

Results

The span is set by the density difference: recalibrate when the liquid changes.

Buoyancy at the level9.4474N
Apparent weight at the level39.586N
Force change over the full range23.535N
Level as a share of the range40.000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 60 mm x 1 m, 5 kg, oil 850, 0.4 m covered. The inputs, in the units selected above:

InputValue
Displacer diameter60.000 mm
Displacer length (measuring range)1.0000 m
Displacer mass5.0000 kg
Liquid density850.00 kg/m³
Vapour density above the liquid1.2000 kg/m³
Level on the displacer (from its bottom)0.40000 m

Applying the formula below gives:

ResultValue
Buoyancy at the level9.4474 N
Apparent weight at the level39.586 N
Force change over the full range23.535 N
Level as a share of the range40.000 %

Open this example in the calculator and change any input.

Formula

\(F_b = g A [\rho h + \rho_v (L - h)], \quad W_a = m g - F_b, \quad \Delta F = g A L (\rho - \rho_v)\)

Variables

Symbol Meaning SI unit
\(d\) Displacer diameter m
\(L\) Displacer length (measuring range) m
\(m\) Displacer mass kg
\(\rho\) Liquid density kg/m³
\(\rho_v\) Vapour density above the liquid kg/m³
\(h\) Level on the displacer (from its bottom) m
\(F_b\) Buoyancy at the level N
\(W_a\) Apparent weight at the level N
\(\Delta F\) Force change over the full range N
\(h/L\) Level as a share of the range -

Method and standards

Archimedes' principle.

Where it is used

  • Level control in drums, separators and condensers.
  • Calibration with water.

Common mistakes

  • Ignoring vapour density at high pressure.
  • Wrong liquid density.

Assumptions and limits

  • Vertical cylindrical displacer; liquid denser than the vapour.
  • A negative apparent weight (the displacer would float) is flagged.

References

  • Archimedes' principle

Questions and answers

What force change does a 60 mm × 1 m displacer give in 850 kg/m³ oil?

23.5 N over the range.

Why does density matter?

Buoyancy is density × displaced volume, so a lighter liquid reads low.

Can displacers measure interface?

Yes, fully submerged, by the density difference of the two liquids.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.