Worked example
Example: 65 / 60 / 52 dBA. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Day Leq (dBA) | 65.000 - |
| Evening Leq (dBA) | 60.000 - |
| Night Leq (dBA) | 52.000 - |
| Day hours (Ldn) | 15.000 - |
| Day hours (Lden) | 12.000 - |
| Evening hours (Lden) | 4.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Day–night level (dBA) | 64.101 |
| Day–evening–night level (dBA) | 64.210 |
| 24-hour Leq without penalties, from the day–evening–night periods (dBA) | 62.554 |
Open this example in the calculator and change any input.
Formula
\(L_{dn} = 10\log_{10}\frac{h_d10^{L_d/10} + (24 - h_d)10^{(L_n + 10)/10}}{24}\) \(L_{den} = 10\log_{10}\frac{h'_d10^{L_d/10} + h_e10^{(L_e + 5)/10} + (24 - h'_d - h_e)10^{(L_n + 10)/10}}{24}\) \(L_{eq,24h} = 10\log_{10}\frac{h'_d10^{L_d/10} + h_e10^{L_e/10} + (24 - h'_d - h_e)10^{L_n/10}}{24}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L_d\) | Day Leq (dBA) | - |
| \(L_e\) | Evening Leq (dBA) | - |
| \(L_n\) | Night Leq (dBA) | - |
| \(h_d\) | Day hours (Ldn) | - |
| \(h_d'\) | Day hours (Lden) | - |
| \(h_e\) | Evening hours (Lden) | - |
| \(L_{dn}\) | Day–night level (dBA) | - |
| \(L_{den}\) | Day–evening–night level (dBA) | - |
| \(L_{eq,24h}\) | 24-hour Leq without penalties, from the day–evening–night periods (dBA) | - |
Method and standards
Energy average with penalties.
Where it is used
- Plant boundary noise reporting.
- Environmental impact assessments.
Common mistakes
- Adding dB arithmetically.
- Forgetting the night penalty.
Assumptions and limits
- Period Leq values measured or predicted. The unpenalised 24-hour Leq uses the three Lden periods, so the evening level counts.
References
- Day–night level (US EPA, 1974) and Lden (EU Directive 2002/49/EC) definitions
Questions and answers
Why penalise night noise?
The same level disturbs sleep far more than daytime activity; 10 dB is about doubling the loudness.
What is a typical limit?
Ldn around 55 dBA protects residential areas from annoyance (WHO guidance).
What do the defaults represent?
A plant boundary with 65 dBA by day, 60 in the evening and 55 at night.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.