Worked example
Example: OSHA: 4 h at 95, 3 h at 88, 1 h at 80 dBA. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Criterion | OSHA: 90 dBA, 5 dB exchange (29 CFR 1910.95) |
| Level of exposure 1 (dBA) | 95.000 - |
| Duration of exposure 1 | 4.0000 h |
| Level of exposure 2 (dBA) | 88.000 - |
| Duration of exposure 2 | 3.0000 h |
| Level of exposure 3 (dBA) | 80.000 - |
| Duration of exposure 3 | 1.0000 h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Noise dose | 131.54 % |
| 8-hour time-weighted average (dBA) | 91.978 |
| Permitted time at level 1 | 4.0000 h |
Open this example in the calculator and change any input.
Formula
\(T = \frac{8\ \text{h}}{2^{(L - L_c)/q}}, \quad D = \sum \frac{C_i}{T_i}, \quad TWA = L_c + \frac{q}{\log_{10} 2}\log_{10} D\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{rule}\) | Criterion | - |
| \(L_1\) | Level of exposure 1 (dBA) | - |
| \(C_1\) | Duration of exposure 1 | s |
| \(L_2\) | Level of exposure 2 (dBA) | - |
| \(C_2\) | Duration of exposure 2 | s |
| \(L_3\) | Level of exposure 3 (dBA) | - |
| \(C_3\) | Duration of exposure 3 | s |
| \(D\) | Noise dose | - |
| \(TWA\) | 8-hour time-weighted average (dBA) | - |
| \(T_1\) | Permitted time at level 1 | s |
Method and standards
Equal-energy (3 dB) or OSHA (5 dB) exchange rule.
Where it is used
- Plant noise surveys.
- Hearing conservation programmes.
Common mistakes
- Mixing exchange rates.
- Unweighted instead of A-weighted levels.
Assumptions and limits
- Steady levels in each period.
- Every level entered is counted; OSHA counts only levels of 80 dBA and above for the action level and 90 dBA and above for the PEL, so enter only those levels for a strict OSHA comparison.
References
- 29 CFR 1910.95 Appendix A (OSHA): T = 8/2^((L − 90)/5)
- D = Σ C/T
- TWA = 16.61 log₁₀(D) + 90
- NIOSH 1998 criterion: 85 dBA
- 3 dB exchange
Questions and answers
4 h at 95, 3 h at 88 and 1 h at 80 dBA (OSHA)?
Dose 132 %, TWA 92.0 dBA.
Why do the rules differ?
OSHA uses a 5 dB exchange; NIOSH and most countries use 3 dB, which is stricter.
What does 100 % mean?
The full permitted daily exposure.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.