Worked example
Example: 6206-type: 9 balls of 12.7 mm, 71.5 mm pitch, 1 480 rpm. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Shaft speed | 1,480.0 rpm |
| Number of rolling elements | 9.0000 - |
| Rolling element diameter | 12.700 mm |
| Pitch diameter | 71.500 mm |
| Contact angle | 0 ° |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ball pass frequency, outer race | 91.284 Hz |
| Ball pass frequency, inner race | 130.72 Hz |
| Ball spin frequency | 67.245 Hz |
| Fundamental train (cage) frequency | 10.143 Hz |
Open this example in the calculator and change any input.
Formula
\(BPFO = \frac{n}{2} f_r (1 - \tfrac{d}{D}\cos\varphi), \quad BPFI = \frac{n}{2} f_r (1 + \tfrac{d}{D}\cos\varphi)\)
\(BSF = \frac{D}{2d} f_r \left[1 - \left(\tfrac{d}{D}\cos\varphi\right)^2\right], \quad FTF = \frac{f_r}{2}(1 - \tfrac{d}{D}\cos\varphi)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(f_r\) | Shaft speed | 1/s |
| \(n\) | Number of rolling elements | - |
| \(d\) | Rolling element diameter | m |
| \(D\) | Pitch diameter | m |
| \(\varphi\) | Contact angle | rad |
| \(BPFO\) | Ball pass frequency, outer race | 1/s |
| \(BPFI\) | Ball pass frequency, inner race | 1/s |
| \(BSF\) | Ball spin frequency | 1/s |
| \(FTF\) | Fundamental train (cage) frequency | 1/s |
Method and standards
Rolling without slip.
Where it is used
- Vibration analysis of pumps, fans and motors.
- Condition monitoring set-up.
Common mistakes
- Using bore instead of pitch diameter.
- Forgetting the contact angle of angular bearings.
Assumptions and limits
- No slip, outer race fixed.
- Rotating outer race with a fixed inner race (some wheel hubs and idlers) is not offered: there the cage turns at f_r/2 (1 + d/D cos φ) and the race frequencies change accordingly.
- The number of rolling elements must be a whole number.
References
- Rolling-bearing kinematics (Harris and Kotzalas, Rolling Bearing Analysis)
Questions and answers
What are the frequencies of a 9-ball bearing, 12.7 mm balls, 71.5 mm pitch, at 1480 rpm?
BPFO 91.3 Hz, BPFI 130.7 Hz.
Where do the dimensions come from?
The bearing maker's catalogue or software.
How are they used?
Peaks at these frequencies in an envelope spectrum point to the damaged part.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.