Worked example
Example: Acidic effluent 20 m³/h, 500 mg/L acidity, 48 % caustic, pH 3. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Effluent flow | 20.000 m³/h |
| Neutralising chemical | Caustic soda NaOH (for acidic effluent) |
| Strength of the chemical as supplied | 48.000 % |
| Acidity or alkalinity to remove, as CaCO₃ (from a titration to the target pH) | 500.00 mg/L |
| Effluent pH, for a strong-acid or strong-base check (0 = none, so a pH of exactly 0 cannot be checked) | 3.0000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Dose of the chemical as supplied | 832.55 mg/L |
| Chemical as supplied | 16.651 kg/h |
| Chemical per day | 399.63 kg |
| Acidity or alkalinity from pH alone (strong acid or base, as CaCO₃) | 50.043 mg/L |
Open this example in the calculator and change any input.
Formula
\(D = A_c \frac{E_r}{E_{CaCO_3}} \cdot \frac{1}{s}\)
\(\dot m_r = D\, Q, \quad m_d = \dot m_r \cdot 86\,400\ \text{s}\)
\(A_{pH} = 10^{-pH} \ \text{(or } K_w / 10^{-pH}\text{) eq/L} \times E_{CaCO_3}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | effluent flow | m³/s |
| \(\text{reagent}\) | neutralising chemical | - |
| \(s\) | strength as supplied | - |
| \(A_c\) | acidity or alkalinity as CaCO₃ | kg/m³ |
| \(pH\) | Effluent pH, for a strong-acid or strong-base check (0 = none, so a pH of exactly 0 cannot be checked) | - |
| \(E_r\) | equivalent mass of the reagent | kg/kmol |
| \(E_{CaCO_3}\) | equivalent mass of CaCO₃ (50.04) | kg/kmol |
| \(K_w\) | ionic product of water at 25 °C | (mol/L)² |
| \(D\) | dose as supplied | kg/m³ |
| \(\dot m_r\) | chemical rate | kg/s |
| \(m_d\) | chemical per day | kg |
| \(A_{pH}\) | acidity from pH alone | kg/m³ |
Method and standards
Acidity measured as CaCO₃ converts to any reagent by the ratio of equivalent masses (NaOH 40.0, Ca(OH)₂ 37.0, Na₂CO₃ 53.0, H₂SO₄ 49.0, HCl 36.5, CaCO₃ 50.0), then to product by its strength. The pH-only figure applies to unbuffered strong acids or bases.
Where it is used
- Sizing neutralisation dosing pumps and tanks.
- Estimating chemical costs for an ETP.
- Neutralising DM plant regeneration waste.
Common mistakes
- Dosing from pH alone on buffered effluent.
- Forgetting the product strength.
- Overshooting with strong reagents in small tanks.
Assumptions and limits
- Dose from titration to the target pH; reaction complete.
References
- Equivalent-weight stoichiometry (acidity as CaCO₃)
Questions and answers
How much 48 % caustic neutralises 20 m³/h with 500 mg/L acidity?
About 830 mg/L of product: 16.7 kg/h or 400 kg/day.
Why titrate instead of using pH?
Real effluents are buffered: their acidity is far more than the free H⁺ that pH shows. pH 3 alone suggests only 50 mg/L as CaCO₃.
Which chemical is cheapest?
Lime is usually cheapest for acids but makes sludge; caustic is cleaner; compare by cost per equivalent.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.