FireCADCalc

Oxygen Requirement of an Activated Sludge Process

Oxygen needed in an activated sludge aeration tank from flow, BOD removed, the BOD₅/BOD_u ratio and biomass wasted, plus oxygen for nitrification.

Refinery and petrochemicalChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 2000 m3/d, no nitrificationWith 25 mg/L ammonia nitrified

Results

Divide the air by the diffuser's field transfer efficiency for the real blower flow.

Oxygen required597.34kg/d
Air at 23.2 % O₂ by mass, 1.2 kg/m³, if all oxygen transferred89.401m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2000 m3/d, no nitrification. The inputs, in the units selected above:

InputValue
Wastewater flow2,000.0 m³/d
Influent BOD₅300.00 mg/L
Effluent soluble BOD₅10.000 mg/L
BOD₅/BOD_u ratio68.000 %
Biomass wasted (as VSS)180.00 kg/d
Ammonia nitrogen nitrified (0 if none)0 mg/L

Applying the formula below gives:

ResultValue
Oxygen required597.34 kg/d
Air at 23.2 % O₂ by mass, 1.2 kg/m³, if all oxygen transferred89.401 m³/h

Open this example in the calculator and change any input.

Formula

\(\dot m_{O_2} = \frac{Q(S_0 - S)}{f} - 1.42P_x + 4.57\,Q\,\Delta N\)

Variables

Symbol Meaning SI unit
\(Q\) Wastewater flow m³/s
\(S_0\) Influent BOD₅ kg/m³
\(S\) Effluent soluble BOD₅ kg/m³
\(f\) BOD₅/BOD_u ratio -
\(P_x\) Biomass wasted (as VSS) kg/s
\(\Delta N\) Ammonia nitrogen nitrified (0 if none) kg/m³
\(\dot m_{O_2}\) Oxygen required kg/s
\(\dot V_a\) Air at 23.2 % O₂ by mass, 1.2 kg/m³, if all oxygen transferred m³/s

Method and standards

Oxygen balance.

Where it is used

  • ETP blower sizing.
  • Operator examinations.

Common mistakes

  • Total instead of soluble effluent BOD.
  • Forgetting nitrification.

Assumptions and limits

  • Steady state.
  • A negative oxygen balance (biomass wasted too large for the BOD removed) is shown as zero and flagged as inconsistent inputs.

References

  • O₂ = Q(S₀ − S)/f − 1.42 P_x + 4.57 Q ΔN (Metcalf & Eddy, Wastewater Engineering)

Questions and answers

2000 m³/d, 300 → 10 mg/L BOD, f 0.68, 180 kg/d wasted?

About 597 kg O₂ a day.

Why subtract 1.42 P_x?

Oxygen bound in the wasted biomass is not consumed.

Nitrification?

Adds 4.57 kg O₂ per kg of ammonia nitrogen oxidised.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.